Sweep speed (time base)
is the
amount of time per division on the
display, and is shown on the status
line. When you vary the Time/Div set-
ting while running an acquisition, the
sample period is also being adjusted.
Thresholds
define the voltage at
which there is a change from low to
high. Thresholds specified can be
TTL, CMOS, or ECL, or variable from
-6.0 V to +6.0 V.
Time base
See “Sweep speed.”
Trigger
is the point that causes
the oscilloscope to begin storing ac-
quisition data. The trigger can be a
signal edge, a pattern, or a combina-
tion of edges, patterns, and
durations. See “Edge trigger,” “Pat-
tern trigger,” or “Advanced trigger.”
Width
refers to positive and nega-
tive duration of a signal. The signal
width can be measured using time
measurements. In doing so, the oscil-
loscope measures the time between
the first set of transitions at the left
side of the visible display that begin
and end the logic high or low value.
See also “Minimum detectable pat-
tern width.”
HP 54645A/D Oscilloscope Terms
Acquisition memory
stores the
acquired sample. This memory is
part of the acquisition subsystem,
and is located in the sample RAM.
Aliasing
is occurring whenever
the waveform display changes more
than expected, as you expand the
time base. Aliasing is due to under
sampling.
Auto
is a trigger mode that pro-
duces a baseline display if the trigger
conditions are not met. If the trigger
frequency is less than 25 Hz, even if
the level and slope conditions are
met, a free-running display will re-
sult.
Auto Level
sets the trigger point
to the 50% amplitude point on the
displayed waveform. If there is no
signal present, a baseline is dis-
played.
Autoscale
performs a simple one-
button setup of the oscilloscope,
including setting the time base and
thresholds and displaying waveforms
for channels connected to active sig-
nals.
Glossary
Glossary-3
Summary of Contents for 54645A
Page 5: ...iv ...
Page 12: ...1 Getting Started ...
Page 25: ...1 14 ...
Page 26: ...2 Front Panel Overview ...
Page 60: ...3 Triggering HP 54645A D Oscilloscopes ...
Page 84: ...4 MegaZoom Concepts and Oscilloscope Operation ...
Page 142: ...5 Making Measurements with HP 54645A D Oscilloscopes ...
Page 176: ...6 Using Option 005 Enhanced TV Video Trigger HP 54645A ...
Page 189: ...6 14 ...
Page 190: ...7 Testing Adjusting and Troubleshooting ...
Page 242: ...8 Replacement Parts ...
Page 259: ...8 18 ...
Page 260: ...9 Performance Characteristics ...
Page 271: ...9 12 ...
Page 272: ...10 Messages ...