HTTP/HTTPS
W
EB
GUI
–
W
EB
B
ROWSER
C
ONFIGURATION
I
NTERFACE
8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00
140 / 178
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
Status
operation mode
time
announcement SZ-WZ-SZ
0 = 0000
INVA
winter
no announcement
1 = 0001
INVA
winter
announcement
2 = 0010
INVA
summer
no announcement
3 = 0011
INVA
summer
announcement
4 = 0100
QUSE / QUEX / QUON
winter
no announcement
5 = 0101
QUSE / QUEX / QUON
winter
announcement
6 = 0110
QUSE / QUEX / QUON
summer
no announcement
7 = 0111
QUSE / QUEX / QUON
summer
announcement
8 = 1000
SYOF
winter
no announcement
9 = 1001
SYOF
winter
announcement
A = 1010
SYOF
summer
no announcement
B = 1011
SYOF
summer
announcement
C = 1100
SYNC
winter
no announcement
D = 1101
SYNC
winter
announcement
E = 1110
SYNC
summer
no announcement
F = 1111
SYNC
summer
announcement
8.3.8.5.6.4.4 Example
(STX)E4123456180702(LF)(CR)(ETX)
•
It is Thursday 18.07.2002 - 12:34:56 o'clock.
•
synchronization status code: SYNC
•
daylight saving time
•
no announcement of a changeover
•
( ) - ASCII-control characters e.g. (STX)
8.3.8.5.6.5 Trimble Time String (TSIP)
The Trimble Time String (TSIP) can be used to synchronize slave systems with the time data
of the master system.
Example in Hex description (not ASCII):
10 8F 0B 00 00 41 0A 49 00 00 00 00 00 13 04 07 E0 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 10 03