
HTTP/HTTPS
W
EB
GUI
–
W
EB
B
ROWSER
C
ONFIGURATION
I
NTERFACE
8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00
116 / 178
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
8.3.7.8 SyncON / SyncOFF Timer
SyncON Timer
The SyncON timer is used to delay the sync-
status “SYNC” by the set time although the GPS
receiver is synchronous.
This function is enabled when adjustment processes should be terminated as defined before
the sync status is “SYNC”.
This function is not required for this device and should always be set to 0.
SyncOFF Timer
This value is used to provide reception failure bypassing for an error-message free operation
even under poor reception conditions.
In the event of a reception failure of the Sync Source (here Module 8024GPS), the decrease
of the Sync Source to
quartz
status is delayed by the set value. The system continues to run
in synchronization status on the internally regulated, highly accurate quartz base during this
period with sync status
'SYOF'
.
This timer is of special significance when certain system outputs are linked to a specific system
status.
The Timer can be set from 2min. to 1440min.
Current Timer values
In case of an active Timer the appropriate value of the timer is displayed here.