S
YSTEM
B
EHAVIOUR
8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00
22 / 178
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
4.4
Firmware Update
The Time Server 8030HEPTA/GPS is a multi-processor system. For this reason a firmware
update always consists of a so called Software SET including three (3) program releases de-
fined by the SET version needed to be loaded into the board.
Module 8030HEPTA (WebGUI: Device):
1x Image Update
upgrade_8030gen_rel_vXXXX.img
1x H8 Update
H8_8030HEPTA_vXXXX_128.mot
Module 8024GPS (WebGUI: Sync Source):
1x H8 Update
8024A_vXXXX_128.mot
An update is a critical process.
The device must not be turned off during the update and the network con-
nection to the device not be interrupted.
All programs of a SET needed to be uploaded to ensure a defined opera-
tion condition.
The program releases assigned to a SET version may be taken from the
release notes of the software SETs of the Time Sever 8030HEPTA/GPS.
4.4.1 Firmware Update 8030HEPTA (WebGUI: Device)
The general process of a software update of Module 8030HEPTA is described below:
For selection of the correct update set the identifier
8030HEPTA
has to be
observed obligatory.
8030HEPTA can be recognized:
•
By the label on the housing cover "
8030HEPTA
"
•
In WebGUI at the Web-banner "
8030HEPTA
"
The firmware update 8030HEPTA has to be performed as a SET.
The software package contained in the file package hopf8030HEPTA_GPS_SET_vXXXX.zip
has to be unpacked. The following steps have to be executed in the following sequence:
1. Image Update 8030HEPTA
2. H8 Firmware Update 8030HEPTA
3. H8 Firmware Update 8024GPS