2.2.3 Reset-(Default) Button
The Reset-(Default) Button is accessible with a thin object
through the small drilling in the front panel next to the "Reset" in-
scription" (see
Chapter 4.3 Reset-(Default) Button
2.2.4 Status LEDs (TS/Error/Operation)
TS-LED
(Green)
Time service of the Time Server
8030HEPTA/GPS
On
Standard
, running
Off
Not or partially not running
ERROR-LED
(Red)
Description
Off
Standard case
,
system 8030HEPTA/GPS is working.
3Hz flashing
Fail-safe basic parameterization is not
available (emergency operation mode)
On
Primary CPU of system 8030HEPTA/GPS
does not show any activity.
Operation-LED
(Green)
Description
On
Standard case
,
system 8030HEPTA/GPS is working
1Hz flashing
System 8030HEPTA/GPS is booting the
operating system.
3Hz flashing
A firmware update (image) of system
8030HEPTA/GPS is being executed.
Off
System 8030HEPTA/GPS is
not
ready for
operation.
2.2.5 USB-Port (Host)
On specific problems the USB connection can be used for a sys-
tem recovery after consulting the
hopf
Support.