• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
Image Update 8030HEPTA
1. Log in as Master in WebGUI of the board.
2. Select in
Device
tab the menu item
Image Update
.
3. Select the file with the file
.img
via the selection window
(Exapmle:
upgrade_8030gen_rel_vXXXX.img
).
4. The selected file is shown in the selection window.
5. The update process is started with the button
Upload now
.
6. In WebGUI the successful file transfer and writing to the Module is indicated.
7. In WebGUI the successful update is indicated after 2-3 minutes with the request to
release a reboot of the board.
8. After activation and successful reboot of the board the image update process is fin-
ished.
H8 Firmware Update 8030HEPTA
1. Log in as Master in WebGUI of the board.
2. Select in the
Device
tab the menu item
H8 Firmware Update
.
3. Select the file with the file extension
.mot for Module 8030
via the selection window
(Example:
H8_8030HEPTA_vXXXX_128.mot
).
4. The selected file is shown in the selection window.
5. The update process is started with the button
Upload now
.
6. In WebGUI the successful file transfer to the Module is indicated.
7. Now the update of the board automatically starts after a few seconds.
8. After successful update the board automatically reboots.
9. After approx. 2 minutes the H8 update process is finished and the board is again ac-
cessible via WebGUI.
4.4.2 Firmware Update 8024GPS (WebGUI: Sync Source)
H8 Firmware Update 8024GPS
1. Log in as Master in WebGUI of the board.
2. Select in the
GPS SYNC SOURCE
tab the menu item
H8 Firmware Update
.
3. Select the file with the file extension
.mot for Module 8024
via the selection window
(Example:
8024A_vXXXX_128.mot
).
4. The selected file is shown in the selection window.
5. The update process is started with the button
Upload now
.
6. In WebGUI the successful file transfer to the Module is indicated.
7. Now the update of the board automatically starts after a few seconds.
8. After successful update the board automatically reboots.
9. After approx. 2 minutes the H8 update process is finished and the board is again ac-