8520CS Signal Selector
NOTE: Now that you have a calibrated 8520CS/8500C/C+ system, you can verify the charge
sensitivity of the Endevco 6233C50 accelerometer. Simply affix this accelerometer to a
calibrated shaker system set for a known vibration level approximately 10 ips (pk) at 100 hz,
sine. Verify the 6233C-50 output on the 8500C/C+.
Figure D-8. Functional Test Setup Charge Converter Amplifier Calibration
Table D-4. Charge Amplifier Adjustments
Channel DIP
Switch
Potentiometer
3
S1
R73
6
S2
R92
9
S3
R111
12