Functional Tests
8500C/8500C+ System Maintenance Manual
5-7
am.
Press
START
key.
an.
Verify that display indicates (example in Figure 5-4):
1800 +2 RPM
0.8 +0.08 IPS
275° +10°
ao.
Press
STOP
key.
ap.
Set
CAM RATE
(RPM)
switch on Calibrator 11A to 900.
aq.
Press
SETUP
key on 8500C/C+.
ar.
Key in
450
in
BALANCE FREQUENCY
field.
as.
Key in
x2
as times factor.
at.
Press
ENTER
soft key.
au.
Wait 10 seconds
av.
Press
START
key.
aw.
Verify the display indicates (example in Figure 5-3):
900 +1 RPM
0.4 +0.04 IPS
275° +10°
ax.
Press
STOP
key.
ay.
Move 11210 cables to next Velocimeter channel positions listed in Table 5-3, and move
cable 10808 to magnetic pickup channel position indicated in table.
az.
Press
SETUP
on 8500C/C+.
ba.
Select
PICKUP
field with arrow keys.
bb.
Press
CHANGE
soft key to select pickup shown in Table 5-3.
bc.
Select
INPUT
field with arrow keys.
bd.
Key in channel number shown in Table 5-3 with numeric key.
be.
Press
ENTER
soft key.
bf.
Wait 10 seconds.