Functional Tests
8500C/8500C+ System Maintenance Manual
D-7
jj.
Press
START
key.
kk.
Verify that display indicates (example in Figure D-3):
1800+2 RPM
0.8+0.08 IPS
275+10°
ll.
Press
STOP
key.
mm.
Repeat steps bb. through ll. for all channels in Table D-2.
D.5.2
8500 Balancer/Analyzer System Test Procedure with 8520CS (Using
High Temp Accelerometers and Photocells)
NOTE: Thes tests build successively on the first test in this section. Any settings not
mentioned must be left as they were in the previous test.
D.5.2.1 Test Setup
a.
Connect equipment as shown if Figure D-4.
NOTE: Make sure calibrator Accelerometer cables are free to move so that Accelerometer
movement is not inhibited.
D.5.2.2 Power-Up Self-Test
b.
Hold down
START
key on 8500C/C+ and turn on power supply.
NOTE: This erases all memory in 8500C/C+.
c.
Wait until
Power-Up Self-Test
display appears and release
START
key.
D.5.2.3 Balance Test
d.
Ensure that the only one piece of reflective tape is installed on the Calibrator 11A rotor
CAM.
e.
Set
CAM RATE (RPM)
switch to
1800
.
f.
Set
MOTOR
switch to
ON
.