22
22
Stripe Hog Systems
Water supply problems to the charge pump can be
indicated by low water pressure or by the sound
of the pump. Fluctuating pump RPM, inconsistent
high pitch whines and fluctuating charge water
pressures are indications of a water supply prob-
lem to the charge pump. If the pressure does not
immediately rise and the pump is whining, im-
mediately turn the charge pump OFF. Make sure
the supply valve is open, check both filters and/or
bleed the air from the system. Operators should
be familiar with the normal sound of the pump
and stop blasting if the sound changes. Find and
correct the problem before water blasting opera-
tions resume.
NOTICE:
THE UHP PUMP CAN CAvITATE IF THE CHARGE WATER
PRESSURE DROPS BELOW 25 PSI (1.7 BAR.) CAvITATION
CAN CAUSE SEvERE DAMAGE TO THE UHP PUMP AND
SHOULD NEvER BE ALLOWED TO OCCUR. YOU SHOULD
ALWAYS MONITOR THE CHARGE WATER PRESSURE AND
NEvER OPERATE THE UHP PUMP WHEN THE CHARGE
WATER PRESSURE DROPS BELOW 30 PSI (2.1 BAR.)
Filters
A two stage filter system in the supply line from
the charge pump to the Ultra-High Pressure pump
protects the high pressure pump and system from
debris or contaminants in the water supply.
Typical Switch Panel & Pressure Gauges In Cab
Digital Charge Water Pressure Gauge In Switch Panel
The first stage filter is a nominal 10 micron bag
filter that traps larger particles. The second stage
is a 1 micron cartridge filter that traps smaller
particles.
Summary of Contents for Stripe Hog SK2000
Page 2: ...2...
Page 6: ...6 NOTES...
Page 142: ...142 NOTES...
Page 147: ...147 Appendix 2 Tools Spare Parts...
Page 148: ...148 Tools Spare Parts...
Page 149: ...149 Appendix 3 Daily Report Pre Op Checklist 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM 60...
Page 158: ...158 NOTES...
Page 165: ......