Diagnostics
[ Diagnostics > Ports > Port Monitor ]
273
RM GUI GRS
Release
8.0
09/2019
6.4.3
Port Monitor
[ Diagnostics > Ports > Port Monitor ]
The
Port Monitor
function monitors the adherence to the specified parameters on the ports. If the
Port
Monitor
function detects that the parameters are being exceeded, then the device performs an
action.
To apply the
Port Monitor
function, proceed as follows:
Global
tab
Enable the
Operation
function in the
Port Monitor
frame.
Activate for each port those parameters that you want the
Port Monitor
function to monitor.
Link flap
,
CRC/Fragments
and
Overload detection
tabs
Specify the threshold values for the parameters for each port.
Link speed/Duplex mode detection
tab
Activate the allowed combinations of speed and duplex mode for each port.
Global
tab
Specify for each port an action that the device carries out if the
Port Monitor
function detects
that the parameters have been exceeded.
Auto-disable
tab
Mark the
Auto-disable
checkbox for the monitored parameters if you have specified the
auto-
disable
action at least once.
The dialog contains the following tabs:
[Link speed/Duplex mode detection]
[
Global
]
In this tab, you enable the
Port Monitor
function and specify the parameters that the
Port Monitor
function is monitoring. Also specify the action that the device carries out if the
Port Monitor
function
detects that the parameters have been exceeded.
Operation
Operation
Enables/disables the
Port Monitor
function globally.
Possible values:
On
The
Port Monitor
function is enabled.
Off
(default setting)
The
Port Monitor
function is disabled.
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......