Figure 3-2 Hole Position Diagram
4. Bury cables. Each lane buries 1 high voltage cable and 1 low voltage cable. For details, see the
system wiring diagram in step 3.
Note
●
High voltage: AC power input
Low voltage: interconnecting cable (communication cable and 24 V power cable) and network
communication cable
●
The supplied interconnecting cable length is 3 m.
●
The suggested inner diameter of the low voltage conduit is larger than 30 mm.
●
If you want to bury both of the AC power cord and the low voltage cable, the two cables
should be in separated conduits to avoid interference.
●
If more peripherals are required to connect, you should increase the conduit diameter or bury
another conduit for the external cables.
●
The external AC power cord should be double-insulated.
●
The interconnecting cable can be CAT5e and CAT6e network cable is suggested for PC
connection.