You can set the following parameters:
Enable Arming
When you enable the function, during the device arming procedure, the system will check the
configured fault checklist. When there is fault occurred during the arming procedure, the
procedure will be stopped.
Note
PKG keypad and the keyfob do not support this function. If this function is enabled, the arming
will fail if there is a fault. It is necessary to eliminate the fault or close the Enable Arming.
Fault Checklist
The system will check if the device has the faults in the checklist during the arming procedure.
Enable Arming with Fault
Check the faults in the Enable Arming with Fault list, and the device will not stop the arming
procedure when faults occurred.
Arming Indicator Keeps Light
If the device applies EN standard, by default, the function is disabled. In this case, if the device is
armed, the indicator will be solid blue for 5 s. And if the device is disarmed, the indicator will
flash 5 times.
When the function is enabled, if the device is armed, the indicator will be on all the time. And if
the device is disarmed, the indicator will be off.
Note
Only -P model supports this function.
Prompt Fault When Arming
If the device applies EN standard, by default, the function is disabled. In this case, the device will
not prompt faults during the arming procedure.
Note
Only -P model supports this function.
Enable Early Alarm
If you enable the function, when the zone is armed and the zone is triggered, the alarm will be
triggered after the delay time.
Note
The early alarm will be taken effect only after the delayed zone is triggered.