Steps
1. Click Device Management → Zone to enter the Zone page.
Figure 4-12 Zone Page
2. Select a zone and click to enter the Zone Settings page.
3. Edit the zone name.
4. Select a zone type.
Instant Zone
This Zone type will immediately trigger an alarm event when armed.
Delayed Zone
Exit Delay: Exit Delay provides you time to leave through the defense area without alarm.
Entry Delay: Entry Delay provides you time to enter the defense area to disarm the system
without alarm.
The system gives Entry/Exit delay time when it is armed or reentered. It is usually used in
entrance/exit route (e.g. front door/main entrance), which is a key route to arm/disarm via
operating keyboard for users.
Note
You can set 2 different time durations in Partition Management → Schedule & Timer .
Ensure that timer is no longer than 45 seconds in order to comply with EN50131-1.
Follow Zone
The zone acts as delayed zone when it detects triggering event during system Entry Delay,
while it acts as instant zone otherwise.
Perimeter Zone
AX Security Control Panel
31