• The processor does not support enhanced processor performance.
• LFF drives with drive capacities greater than or equal to 10 TB are not supported for the Apollo r2200 Gen10 Chassis
series with three drives per node.
Description
Chassis
Fan configuration
Number of drives
supported by the server
Maximum inlet
ambient
temperature
Processor with a
TDP of 125 W or
more, except
G6244
Apollo r2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
3 drives
30°C (86°F)
3 drives
25°C (77°F)
35°C (95°F)
Apollo r2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 6 drives
35°C (95°F)
Apollo r2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
35°C (95°F)
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 4 drives
35°C (95°F)
Intel Xeon Gold
6244
Apollo r2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
3 drives
25°C (77°F)
3 drives
Not supported
30°C (86°F)
Apollo r2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 6 drives
28°C (82.4°F)
Table Continued
Specifications