• The processor does not support enhanced processor performance.
• LFF drives with drive capacities greater than or equal to 10 TB are not supported for the Apollo r2200 Gen10 Chassis
series with three drives per node.
Description
Chassis
Fan configuration
Number of drives
supported by the server
Maximum inlet
ambient
temperature
Processor with a
TDP of 135 W
or more, except
G6244
Apollo r2200 Gen10
Chassis
(12 LFF backplane)
Redundant and
nonredundant
3 drives
28°C (82.4°F)
3 drives
Not supported
0 to 2 drives
35°C (95°F)
Apollo r2600 Gen10
Chassis
(24 SFF or 16 SFF + 8
NVMe backplane)
Redundant and
nonredundant
0 to 6 drives
30°C (86°F)
Apollo r2800 Gen10
Chassis
(24 SFF backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
30°C (86°F)
Apollo r2800 Gen10
Chassis
(16 NVMe backplane)
Redundant and
nonredundant
0 to 4 drives
30°C (86°F)
Intel Xeon Gold
6244
Apollo r2200 Gen10
Chassis
(12 LFF backplane)
Redundant and
nonredundant
3 drives
Not supported
3 drives
Not supported
0 to 2 drives
Not supported
Apollo r2600 Gen10
Chassis
(24 SFF or 16 SFF + 8
NVMe backplane)
Redundant and
nonredundant
0 to 6 drives
Not supported
Apollo r2800 Gen10
Chassis
(24 SFF backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
Not supported
Apollo r2800 Gen10
Chassis
(16 NVMe backplane)
Redundant and
nonredundant
0 to 4 drives
Not supported
Processor with a
TDP between
115 W and 130
W
Apollo r2200 Gen10
Chassis
(12 LFF backplane)
Redundant and
nonredundant
3 drives
30°C (86°F)
3 drives
Not supported
0 to 2 drives
35°C (95°F)