Description
Chassis
Fan configuration
Number of drives
supported by the server
Maximum inlet ambient
temperature
(12 LFF
backplane)
Not supported
25°C (77°F)
Apollo r2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 6 drives
Not supported
22°C (71.6°F)
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 24 drives
Not supported
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 4 drives
22°C (71.6°F)
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
If the component is installed in server 1 or server 2, and the server is installed in the Apollo r2200 Gen10 Chassis, drive blanks must be
installed in drive bays 1-2 and 2-2. Similarly, if the component is installed in server 3 or server 4, and the server is installed in the Apollo
r2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and 4-2.
If the component is installed in server 1 or server 2, and the server is installed in the Apollo r2200 Gen10 Chassis, bezel blanks must be
installed in drive bays 1-2 and 2-2. Similarly, if the component is installed in server 3 or server 4, and the server is installed in the Apollo
r2200 Gen10 Chassis, bezel blanks must be installed in drive bays 3-2 and 4-2.
If the component is installed in server 1 or server 2, and the server is installed in the Apollo r2600 Gen10 Chassis, bezel blanks must be
installed in drive bays 1-3, 1-4, 1-5, 1-6, 2-3, 2-4, 2-5 and 2-6. Similarly, if the component is installed in server 3 or server 4, and the
server is installed in the Apollo r2600 Gen10 Chassis, bezel blanks must be installed in drive bays 3-3, 3-4, 3-5, 3-6, 4-3, 4-4, 4-5 and
4-6.
HPE Smart Array controllers
CAUTION: To prevent improper cooling and thermal damage, do not keep an energy pack inside the chassis when
the Smart Array P-class controller is not installed.
Description
Chassis
Fan configuration
Number of drives
supported by the server
Maximum inlet ambient
temperature
P408i-p
controller
Apollo r2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
3 drives
22°C (71.6°F)
3 drives
Not supported
0 to 2 drives
30°C (86°F)
Table Continued
114
Specifications
Summary of Contents for HPE ProLiant XL170r Gen10
Page 6: ...Acronyms and abbreviations 128 6...
Page 22: ...22 Customer self repair...
Page 23: ...Customer self repair 23...
Page 24: ...24 Customer self repair...