Fibre Channel and Converged Network adapters
Description
Chassis
Fan configuration
Number of drives
supported by the server
Maximum inlet ambient
temperature
FC HBA
Apollo r2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
3 drives
Not supported
3 drives
Not supported
0 to 2 drives
28°C (82.4°F)
Apollo r2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 6 drives
25°C (77°F)
Apollo r2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
25°C (77°F)
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 4 drives
25°C (77°F)
CNA
Apollo r2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
3 drives
Optical cable: Not
supported
Copper cable: 30°C (86°F)
3 drives
Optical cable: Not
supported
Copper cable: 25°C (77°F)
0 to 2 drives
Optical cable: 28°C
(82.4°F)
Copper cable: 35°C (95°F)
Apollo r2600
Gen10 Chassis
(24 SFF or 16
SFF + 8 NVMe
backplane)
Redundant and
nonredundant
0 to 6 drives
Optical cable: 25°C (77°F)
Copper cable: 35°C (95°F)
Table Continued