Description
Chassis
Fan configuration
Number of drives
supported by the server
Maximum inlet ambient
temperature
(12 LFF
backplane)
0 to 2 drives
35°C (95°F)
Apollo r2600
Gen10 Chassis
(24 SFF or 16 SFF
+ 8 NVMe
backplane)
Redundant and
nonredundant
0 to 6 drives
30°C (86°F)
Apollo r2800
Gen10 Chassis
(24 SFF backplane
with SAS
expander)
Redundant and
nonredundant
0 to 24 drives
30°C (86°F)
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 4 drives
Not supported
E208e-p
Controller
Apollo r2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
28°C (82.4°F)
Not supported
0 to 2 drives
35°C (95°F)
Apollo r2600
Gen10 Chassis
(24 SFF or 16 SFF
+ 8 NVMe
backplane)
Redundant and
nonredundant
0 to 6 drives
30°C (86°F)
Apollo r2800
Gen10 Chassis
(24 SFF backplane
with SAS
expander)
Redundant and
nonredundant
0 to 24 drives
30°C (86°F)
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 4 drives
30°C (86°F)
An energy pack is supported only with P408i-p and P408e-p controllers. Due to thermal concerns, HPE recommends removing the
energy pack if these controller type cards are not installed in the chassis.
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
Specifications
103
Summary of Contents for HPE ProLiant XL170r Gen10
Page 6: ...Acronyms and abbreviations 128 6...
Page 22: ...22 Customer self repair...
Page 23: ...Customer self repair 23...
Page 24: ...24 Customer self repair...