Selecting an advanced fan cooling method
Procedure
1. During the server startup sequence, press the F9 key to access System Utilities.
2. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Advanced
Options > Fan and Thermal Options > Thermal Configuration.
3. Select one of the advanced fan cooling method:
•
Enhanced CPU Cooling
•
Maximum Cooling
4. Press F10 to save the configuration.
Disconnecting and replacing the SUV cable
Procedure
1. Disconnect the peripheral devices connected to the SUV cable.
2. Disconnect the SUV cable:
a. Press and hold both sides of the SUV connector.
b. Disconnect the cable from the SUV port.
To replace the component, reverse the removal procedure.
Removing and replacing the bayonet boards
CAUTION: Before replacing a DIMM, expansion board, or other similar PCA components due to a perceived
hardware error, make sure first that the component is firmly seated in the slot. Do not bend or flex circuit boards
when reseating components.
Prerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.