Section 4
♦
Operating the CMN-41
50
CMN-41 Series Installation and Operation Handbook
Copyright © 2009, Harris Corporation
Figure 4-30. Four Bar Graph with Lissajous Display Diagram
Table 4-10. Description of Four Bar Graph with Lissajous Display Diagram
Field
Identifier
Field Information
Nomenclature
1
Input
Displays selected input (A or B)
2
Status
Displays audio type as Mute, AES, or Embedded
Displays audio clip or mute alarm indicators
3
Channel Number
Shown as 1-16 (AES is 1-2 and Embedded is 1-16)
4
Device
Displays labels for lissajous, bar graphs, and headphone
outputs
5
Lissajous Display (2)
Lissajous of bar graph 2 with labels for R, L, and the
number of the meter being monitored (for example, M-2)
6
Lissajous Display (1)
Lissajous of bar graph 1 with labels for R, L, and the
number of the meter being monitored (for example, M-1)
7
Zoom
Zoom (when enabled); blank when disabled
8
Scale Selection
Displays the selected meter scale: Type I, Type IIa, Type
IIb, Type I + 8, Nordic, DIN 45406, dBFS, Zero REF dBFS,
Custom dB, and Custom dBFS
9
Level Markers
Shows peak and reference levels for the signal; this can be
adjusted in the Audio
→
Meter Setup selection options
10
Meter Response
Displays selected meter response: VU, Peak, True Peak,
VU + Peak, VU + True Peak, Custom
11 Audio
Graticule
(with
meter labels)
Shown as L1, R1, L2, and R2 (or Custom label)
12
Phase Bar (1)
Phase Meter of bar graph 1
13
Phase Bar (2)
Phase Meter of bar graph 2