Section 2
♦
Installation
CMN-41 Series Installation and Operation Handbook
11
Copyright © 2009, Harris Corporation
Ethernet Setup
NOTE
: The Ethernet default settings for the CMN-41 are as follows:
IP: 192.0.0.100
Subnet Mask: 255.255.255.192
Gateway: 255.255.255.255
1.
Prior to performing the CMN-41 network configuration, obtain TCP/IP addresses
from the system administrator or the Internet service provider (ISP). These
addresses are a static IP address (unless using Dynamic Host Configuration
Protocol [DHCP]), a subnet mask, and an optional gateway IP.
Be sure to record all addresses in the spaces provided below. The gateway address
is not needed unless the CMN-41 is routed to an outside network.
Record the addresses:
CMN-41 Interface Static IP Address
CMN-41 Interface Subnet Mask
Gateway IP Address
2.
Identify a host PC to configure and test the CMN-41.
3.
Choose a dedicated PC connection or network connection method:
•
For a dedicated PC connection, connect the host PC with a network card to the
“ENET” connector on the back panel of the CMN-41, using a CAT5 crossover
cable (not included). See
Figure 2-3
.
Figure 2-3. CMN-41 Dedicated PC Connection