Section 6
♦
Alarm Descriptions
92
CMN-41 Series Installation and Operation Handbook
Copyright © 2009, Harris Corporation
Table 6-2. Video Alarms Setup Menu
NOTE
: Descriptions for these selection options start on page 94.
Selection
Selection Option
Selection Option
Selection Option
Timing Enable
Lines
0 to 50 lines (1 line *)
Microseconds
1 to 64
μ
s (1
μ
s *)
Duration
0 to 60 seconds (2
seconds *)
Table 6-3. Audio Alarms Setup Menu
NOTE
: Descriptions for these selection options start on page 96.
Selection
Selection Option
Selection Option
Peak Audio
Enable Channel 1
•
•
Enable Channel 16
Level
–30 to 0 dBFS (–10 dBFS *)
Duration
0 to 60 seconds (2 seconds *)
Phase
Enable Pair 1
•
•
Enable Pair 8
Value
0 degrees to 178 degrees *
Duration
0 to 60 seconds (2 seconds *)
Loss of Sound
Enable Channel 1
•
•
Enable Channel 16
Level
–60 * to 0 dBFS
Duration
0 to 60 seconds (2 seconds *)
Loss of AES Data
Enable
Duration
0 to 60 seconds (2 seconds *)
Loss of Embedded Data
Enable Group 1 Pair 1
Enable Group 1 Pair 2
Enable Group 2 Pair 1
Enable Group 2 Pair 2
Enable Group 3 Pair 1
Enable Group 3 Pair 2
Enable Group 4 Pair 1
Enable Group 4 Pair 2
Duration
0 to 60 seconds (2 seconds *)
Continuous Tone
Enable Channel 1
•
•
Enable Channel 16
Threshold
1 * to 20 dB
Duration
0 to 60 seconds (2 seconds *)