Section 6
♦
Alarm Descriptions
CMN-41 Series Installation and Operation Handbook
91
Copyright © 2009, Harris Corporation
Table 6-2. Video Alarms Setup Menu
NOTE
: Descriptions for these selection options start on page 94.
Selection
Selection Option
Selection Option
Selection Option
Peak Gamut Upper
Enable
Threshold 525/59.94
50 to 140 IRE
(120 IRE *)
Threshold 625/50
51 to 143 Units + mV
setting (123 Units *)
Sensitivity
1 to 20 CES
(15 CES *)
Duration
0 to 60 seconds (2
seconds *)
Peak Gamut Lower
Enable
Threshold 525/59.94
–40 to 0 IRE
(–20 IRE *)
Threshold 625/50
–40 to 0 Units + mV
setting (–20 Units *)
Sensitivity
1 to 20 CES
(15 CES *)
Duration
0 to 60 seconds (2
seconds *)
CRC-HD Enable
Duration
0 to 60 seconds (2
seconds *)
EDH-SD Enable
Duration
0 to 60 seconds (2
seconds *)
Letterbox-SD
Enable Top Border
Top Border 525/59.94
Line 21 * to Line 139
Top Border 625/50
Line 19 * to Line 159
Enable
Bottom
Border
Bottom Border 525/59.94
Line 140 * Line to 262
Bottom Border 625/50
Line 160 * to Line 312
Threshold
10 to 350 mV
(286 mV *)
Duration
0 to 60 seconds
(2 seconds *)
Pillarbox-HD
Enable Left Border
Left Border
Pixel 1 * to 860
Enable Right Border
Right Border
Pixel 861 to 1920 *
Threshold
10 to 350 mV (286
mV *)
Duration
0 to 60 seconds (2
seconds *)
Picture Shift
Enable
Threshold
0 to 350 mV (2 mV *)
Vertical
1 to 200 lines (2
lines *)
Horizontal
1 to 300 pixels (2
pixels *)