7 - Fault finding
187
ISOBUS Modules
Modules not found
Configuration cannot be loaded due to the
missing HARDI® C2C Module.
Display is not detecting module.
Check that:
•
Implement is connected to the tractor or that
the JobCom has power and is powered On.
•
Check that the “Enable Task Controller” is
enabled in the ISOBUS Settings menu. Refer
to “Enable Universal Terminal and Task
Controller” on page 45.
Some Modules Not found:
Configuration can be loaded but is not
detecting all the modules associated with the
configuration. When loaded, it will not perform the
functions of the missing modules.
Display is detecting module.
Display is not detecting module.
An example of an application configuration is
shown. The HARDI® C2C Module is detected by the
display but the Norac UC5 Module are not.
It is possible to start a “Field Operation” but the
AutoTerrain/AutoHeight will not be functional.
All Modules Detected - Not all Modules are the
same as previously used
Configuration has a module that was not used
previously.
Module is not the one that was previously
used.
Operating Configuration Selection
Alpha 4100
Equipment
Name
Vehicle
Alpha 4100
Device
Hardi
Hardi C2C Module: Not found
Container
Device
Main Tank
Boom Height
Norac UC5 Module: Not found
Boom Height
Operating Configuration Selection
Alpha 4100
Equipment
Name
Vehicle
Alpha 4100
Device
Hardi
Hardi C2C Module
Container
Device
Main Tank
Boom Height
Norac UC5 Module: Not found
Boom Height
Operating Configuration Selection
Alpha 4100
Equipment
Name
Vehicle
Alpha 4100
Device
Hardi
Hardi C2C Module
Container
Device
Main Tank
Boom Height
Norac UC5 Module: Serial number does not match expected
Boom Height
Summary of Contents for HC 9600
Page 2: ......
Page 4: ......
Page 12: ...2 Safety Notes 10...
Page 32: ...3 Description 30...
Page 182: ...5 Operation 180...
Page 184: ...6 Maintenance 182...
Page 198: ...7 Fault finding 196...
Page 202: ...8 Technical specifications 200...
Page 210: ...Index 208...
Page 211: ......