Dimension of running surface
length x width
1500 x 500 mm
Dimension frame
length x width x height
(UserTe 150 mm width)
2100 x 800 x 1370 mm
2200 x
1000 x
1440 mm
Track access height from floor
180 mm
Weight of device
180 kg
190 kg
190 kg
200 kg
350 kg
380 kg
Weight load limits to floors
(traffic load to DIN 1055 part 3)
8.1 kN/m²
8.2 kN/m²
9.1 kN/m²
9.2 kN/m²
In case of any further questions related to load limits onto floors, please ask our service department.
Max. permissible user weight
200 kg (deviation on request specially made)
Environmental conditions:
Transport and storage
temperature: –30...+50 °C
humidity: 0...95% - without condensation
barometric pressure: 700...1060hPa
Environmental conditions:
Operation
temperature: +10...+40 °C (deviation on request)
humidity: 30...70% - without condensation (up to 95% on request)
barometric pressure: 700...1060hPa
Maximum operating altitude: approx. 10,000 feet (3000m), without pressurization
Pollution degree
Degree 2: Normally only nonconductive pollution. Temporary conductivity caused by condensation is to be expected.
Central lubrication system
manual
Store program space
6 training profiles / 10 test profiles / 8 user definable profiles
RS232 Digital interface / serial port
(USB-converter optional)
COM1: standard;
COM2: option;
COM3: optional (standard for service);
COM4: option (not for locomotion models)
COM1, COM2:
standard
COM3: standard
(for service)
Heart rate measurement
POLAR, 1 channel receiver, ECG precisely
POLAR W.I.N.D.
PC software
(not for medical applications)
h/p/cosmos para control
®
included
options: h/p/cosmos para graphics
®
, h/p/cosmos para analysis
®
and h/p/cosmos para motion
®
Reverse belt rotation / downhill
1
not applicable
option
not applicable option
option standard
Safety Arch with harness***
option
Handrails
options: short / long / adjustable handrails, crossbar
no options
Arm support
option
not applicable
additional keyboard
option
standard
* Overload and weak power supply (undervoltage) could lead to higher discrepancies concerning the speed-display or dripping of the fuse. ** The time of
operation of the elevation motor (TO = 15 %) converts to approx. 5 full elevation cycles. Overload can result in temporary tripping of the fuse, but can be
used again after short cool down period. Treadmills with a running surface 150/50 built approx. before June 2007 have a maximum elevation of 24%.
*** For maximum stress tests and with oversize running machines (track sizes) a safety facility (e.g. a safety harness with chest belt) is necessary and highly
recommended. When using a front-bar handrail (crossbar), the speed is limited to 5 km/h for safety reasons. Data of weight and measurements can deviate.
Ask for further details and optional equipment or visit www.h-p-cosmos.com. Subject to technical alterations without prior notice. E & EO.