optional settings
file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc
© 2012 h/p/cosmos sports & medical gmbh [email protected] created 15.02.2012 printed 15.02.2012 page: 111 of 213
[8.B1]
Continuation…
N
Running machine series h/p/cosmos quasar with
special speed 45 km/h:
Speed Calibration Value: 2.874
Inverter Frequency:
125 Hz
N
Running machine series h/p/cosmos pulsar 3p with 40 km/h:
Speed Calibration Value: 2.874
Inverter Frequency:
110 Hz
N
Running machine series h/p/cosmos pulsar 3p with
special speed 45 km/h:
Speed Calibration Value: 2.874
Inverter Frequency:
125 Hz
OP35 Oil
Interval
The distance interval for indication of "OIL" service required can be
adjusted by means of option 35.
Standard = 1000 km for treadmills, 100 km for ladder-ergometers. OIL
intervals are indicated with error code "E01" "OIL" every 1000 km.
§
reports: oil interval in km (Standard = 1.000)
~
km is flashing
Adjustment range: OFF, 100 ... 5.000 km
Do not change the interval without prior communication with
h/p/cosmos. For the models h/p/cosmos venus, saturn und orbiter,
JAEGER LE 580 and bigger as well as COSMED T200 and bigger
option number 35 is not adjustable, as the machines are equipped with
an automatic oil pump and a tank.