Appendix C– DTR Remote M&C Protocol
CG-6073 (Rev R, June, 2012)
21
ECHO
Path:
/ CONFIGS COMM-PARAM PORT-1 ECHO
Type:
Data Editor
Syntax:
ECHO [= n] | [D]
Range:
Integer:
0 .. 1
0
Disabled
1
Enabled
Notes:
ECHO, when enabled, returns the received character to the port.
ECHO
Path:
/ CONFIGS COMM-PARAM PORT-2 ECHO
Type:
Data Editor
Syntax:
ECHO [= n] | [D]
Range:
Integer:
0 .. 1
0
Disabled
1
Enabled
Notes:
ECHO, when enabled, returns the received character to the terminal.
FACTORY BURN-IN
Path:
/ TESTS FACTORY-BURN-IN
Type:
Executable
Syntax:
FACTORY-BURN-IN
Notes:
Factory burn-in is used to sweep through frequency ranges of all the configured
bands. If the unit contains BDCs, then only the bands associated with those
BDCs are used. If there are no BDCs, then only the L-Band frequency range is
used. While burning in, the alarm "Factory burn-in" is set to indicate that the
unit is not in normal operation. While in burn-in, the menu portion of the display is
used to show the progress of the burn-in process. For a given band, the entire
frequency range is swept in 30 minutes, with a frequency step occurring every 10
seconds. The frequency the unit is set to is upon on entering burn-in is restored when
burn-in is exited. Press PREV or the top soft menu key to exit burn-in.
Summary of Contents for CG-1220
Page 6: ...vi THIS PAGE INTENTIONALLY LEFT BLANK...
Page 10: ...Table of Contents x THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ......
Page 54: ...Maintenance 5 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 56: ...Engineering Drawings 6 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 65: ...Appendix C DTR Remote M C Protocol CG 6073 Rev R Jun 2012 4 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 130: ...Remote M C Protocol C 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 134: ...Acronyms Abbreviations D 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...