Appendix C– DTR Remote M&C Protocol
CG-6073 (Rev R, June, 2012)
39
RATE
Path:
/ CONFIGS MONOPULSE
Type:
Data Editor
Syntax:
RATE [= n] | [D]
Range:
Integer:
-1 .. 10000
Notes:
RATE is the minimum number of milliseconds between the monopulse data
transmissions of START. If the value is -1, new data is sent only after receiving a
carriage return. NOTE: Also used by M&C in TRL-Emulation
RECEIVER OPERATION
Path:
/ CONFIGS OPERATION
Type:
Sub Menu
Syntax:
OPERATION
Notes:
RECEIVER OPERATION configures how the Signal Processing Unit (SPU) will
process the signal.
REMOTE CONTROL
Path:
/ CONFIGS COM-PARAM REM-CONTROL
Type:
Data Editor
Syntax:
REM-CONTROL [= n] | [D]
Range:
Integer:
0 .. 3
0
I/O INTF #1
1
PORT 1
2
PORT 2
3
PORT 3
Notes:
REMOTE CONTROL selects which port on back panel is in control when the DTR is
in REMOTE mode. For remote M&C communications select PORT 1, 2, or 3 which
support serial protocols. To control the DTR via discrete digital I/O select I/O INTF
#1, which will allow a remote device (such as 7134ACU) to select a BEACON using
a cable connected to I/O INTERFACE #1 on the back panel and the
STORE/RESTORE BEACONS menus. The pinout of I/O INTERFACE # 1 includes:
Pins 5,18, GPIO 0, = Beacon 1 Input; Pins 6,19, GPIO 1, = Beacon 2 Input; Pins
7,20, GPIO 2, = Beacon 3 Input; Pins 8,21, GPIO 3, = Beacon 4 Input.
Summary of Contents for CG-1220
Page 6: ...vi THIS PAGE INTENTIONALLY LEFT BLANK...
Page 10: ...Table of Contents x THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ......
Page 54: ...Maintenance 5 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 56: ...Engineering Drawings 6 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 65: ...Appendix C DTR Remote M C Protocol CG 6073 Rev R Jun 2012 4 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 130: ...Remote M C Protocol C 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 134: ...Acronyms Abbreviations D 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...