Operation
4-10
CG-1220 DTR
PORT 1, PORT 2 –
These two menus configure the port for M&C
communications. Port 1 is RS-232 only, while Port 2 allows RS-232 or RS-
422 connections. See Table 3-6 for factory set data parameters for these
ports. The following submenus are configurable for M&C communications:
BPS (BAUD) –
The transfer rate of Port 1 can be set from 1200 to
57,600 BPS. The transfer rate of Port 2 can be set from 1200 to
115,200 BPS.
NEWLINE –
When enabled, a carriage return line-feed (CR-LF) is sent at
the end of the command line. When disabled, only a carriage return (CR)
is sent.
ECHO
returns the received character to the port.
SHELL
determines the communications protocol used on this serial port.
DISABLED disables the serial port. M&C SHELL provides Monitor and
Control protocol support including status polling and system configuration
capability. 72xx M&C Shell provides TRL Monitor and Control protocol
support for status polling and system configuration by a 72xx ACU with
version 2 firmware. An ACU remote port set to DTR and a DTR set to
72xx M&C SHELL will NOT communicate. MESSAGE PRINTER is a
diagnostic tool which may be used to record system events when
connected to a terminal program or a serial printer. TBT INTERFACE
(Optional) supports serial control of GDST Tracking Band Translator
(TBT).
RESET PORT
resets the given port. The communication interface is
reinitialized and the shell (if any) that was running on it is restarted.
PORT 3 –
This menu configures the RS-485 Port 3 for M&C
communications. See Table 3-9 for factory set data parameters for this
port. The following submenus are configurable for M&C communications:
BPS (BAUD) –
The transfer rate of Port 3 can be set from 1200 to
115,200 BPS.
SHELL
determines the communications protocol used on this serial port.
DISABLED disables the serial port. M&C SHELL provides Monitor and
Control protocol support including status polling and system configuration
capability.
MASTER ADDRESS
is the address of the master (controlling) device on
the multi-drop RS-485 bus. There are a maximum of 32 addresses,
ranging from 0 to 31. On the bus, the actual ASCII value used for
addressing is the address assigned here plus the value of the parameter
ADDRESS OFFSET.
Summary of Contents for CG-1220
Page 6: ...vi THIS PAGE INTENTIONALLY LEFT BLANK...
Page 10: ...Table of Contents x THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ......
Page 54: ...Maintenance 5 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 56: ...Engineering Drawings 6 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 65: ...Appendix C DTR Remote M C Protocol CG 6073 Rev R Jun 2012 4 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 130: ...Remote M C Protocol C 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 134: ...Acronyms Abbreviations D 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...