Appendix C– DTR Remote M&C Protocol
CG-6073 (Rev R, Jun, 2012)
44
SLAVE ADDRESS (v 1.19.06 or later)
Path:
/ CONFIGS COMM-PARAM PORT-3 SLAVE-ADDRESS
Type:
Data Editor
Syntax:
SLAVE-ADDRESS [= n] | [D]
Range:
Integer: 0 .. 31
Notes:
SLAVE-ADDRESS is the address of this unit (a slave, controlled) on the multi-drop
RS-485 bus. There are a maximum on 32 addresses, ranging from 0 to 31. On the
bus, the actual ASCII value used for addressing is the address assigned here plus
the value of the parameter ADDRESS OFFSET.
SLOPE
Path:
/ CONFIGS OPERATION ANALOG-OUTPUTS DAC1 DAC1-SLOPE
Type:
Data Editor
Syntax:
DAC1-SLOPE [= n] | [D]
Range:
Real: -1.000 .. 1.000 (volts/dB)
Notes:
SLOPE controls the rate of change of the DC output voltage with respect to a 1 dB
change in signal power level.
SLOPE
Path:
/ CONFIGS OPERATION ANALOG-OUTPUTS DAC2 DAC2-SLOPE
Type:
Data Editor
Syntax:
DAC2-SLOPE [= n] | [D]
Range:
Real: -1.000 .. 1.000 (volts/dB)
Notes:
SLOPE controls the rate of change of the DC output voltage with respect to a 1 dB
change in signal power level.
Summary of Contents for CG-1220
Page 6: ...vi THIS PAGE INTENTIONALLY LEFT BLANK...
Page 10: ...Table of Contents x THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ......
Page 54: ...Maintenance 5 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 56: ...Engineering Drawings 6 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 65: ...Appendix C DTR Remote M C Protocol CG 6073 Rev R Jun 2012 4 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 130: ...Remote M C Protocol C 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 134: ...Acronyms Abbreviations D 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...