Installation
3-4
CG-1220 DTR
TABLE 3-2
I/O INTERFACE 1, STANDARD & WIDEBAND CONFIG.
PIN NUMBER
DESIGNATION
FUNCTION
1,14
+OUT, -OUT (DAC#1)
Analog Output Voltage #1, Common
2
SHLD_OUT
Shield for +/- OUT pair
3,16
+AUX, -AUX (DAC#2)
Analog Output Voltage #2, Common
15
SHLD_AUX
Shield for +/- AUX pair
4,17
SUM_FLT
Summary fault relay contacts.
5,18
GPIO 0, (Beacon 1, Common) Beacon 1 Input
6,19
GPIO 1, (Beacon 2, Common) Beacon 2 Input
7,20
GPIO 2, (Beacon 3, Common) Beacon 3 Input
8,21
GPIO 3, (Beacon 4, Common) Beacon 4 Input
9,22
GPIO 4 (Command, Return)
POL 3 select control line (Multi Port Option Only)
10,23
GPIO 5 (Command, Return)
POL 4 select control line (Multi Port Option Only)
11,24
GPIO 6, (Command, Return)
POL 1 select control line
12,25
GPIO 7, (Command, Return)
POL 2 select control line
13
SIG_GND (Reserved signal)
DTR signal ground; THIS IS NOT A SAFETY GROUND POINT
TABLE 3-3
I/O INTERFACE 2, STANDARD & WIDEBAND CONFIG.
PIN NUMBER
DESIGNATION
FUNCTION
1,14
+OUT, -OUT (DAC#1)
Analog Output Voltage #1, Common
2
SHLD_OUT
Shield for +/- OUT pair
3,16
+AUX, -AUX (DAC#2)
Analog Output Voltage #2, Common
15
SHLD_AUX
Shield for +/- AUX pair
4,17
SUM_FLT
Summary fault relay contacts.
5,18
GPIO 8 (Command, Return)
POL 5 Select Control Line (Multi Port Option Only)
6,19
GPIO 9 (Command, Return)
POL 6 Select Control Line (Multi Port Option Only)
7,20
GPIO 10
General purpose I/O
8,21
GPIO 11
General purpose I/O
9,22
GPIO 12
General purpose I/O
10,23
GPIO 13
General purpose I/O
11,24
GPIO 14
General purpose I/O
12,25
GPIO 15
General purpose I/O
13
SIG_GND (Reserved signal)
DTR signal ground; THIS IS NOT A SAFETY GROUND POINT
3.3.1.1.1
Analog Output Voltage Pin-Out
There are two separate analog voltage outputs available; both are capable of
pro/- 10 VDC. Pins 1, 14 and 2 provide the analog output voltage,
common, and shield connections respectively for DAC # 1. Pins 3, 16 and 15,
respectively, provide an auxiliary analog output for DAC # 2.
3.3.1.1.2 Summary
Fault
Output
Pins 4 and 17 provide the SUMMARY FAULT relay contact closure in the standard
product model. If any faults occur or DTR supply power is lost, the Summary fault
contact will open. The ACKNOWLEDGE FAULTS menu has the effect of removing
Summary of Contents for CG-1220
Page 6: ...vi THIS PAGE INTENTIONALLY LEFT BLANK...
Page 10: ...Table of Contents x THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ......
Page 54: ...Maintenance 5 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 56: ...Engineering Drawings 6 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 65: ...Appendix C DTR Remote M C Protocol CG 6073 Rev R Jun 2012 4 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 130: ...Remote M C Protocol C 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 134: ...Acronyms Abbreviations D 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...