EN-14 Link Duplex
Option:
Function:
Forces the duplex for each port to full or half
duplex. If
parameter EN-12 Auto Negotiation
is
set to: [ON], this parameter is read-only.
[0]
Half Duplex
[1]
*
Full Duplex
EN-20 Control Instance
Range:
Function:
[None, 20, 21, 23,
100, 101, 103]
Read-only. Displays the connection to the
master. In Ethernet/IP: If no CIP
connection is present,
None
is displayed.
EN-21 Process Data Config Write
Range:
Function:
[[0 - 9] PCD read 0 - 9] Configuration of readable process
data.
EN-22 Process Data Config Read
Range:
Function:
[[0 - 9] PCD read 0 - 9] Configuration of readable process
data.
EN-27 Primary Master
Range:
Function:
0
*
[0 -
4294967295]
Controls the Master’s access to the process
data. The value zero (0.0.0.0) means that
other masters can take control of the drive
immediately if the connection is lost or
closed. Setting an IP number means that
only a master with this value can establish a
connection for controlling the drive. In
systems with backup masters, this parameter
should be left to the value zero (0.0.0.0).
EN-28 Store Data Values
Option:
Function:
This parameter activates a function that stores
all parameter values in the non-volatile memory
(EEPROM) thus retaining parameter values at
power-down.
The parameter returns to [0] Off.
[0]
*
Off
The store function is inactive.
[1]
Store All
set-ups
All parameter values are stored in the non-
volatile memory, in all 5 set-ups.
EN-29 Store Always
Option:
Function:
Activates function that always stores received
parameter data in non-volatile memory (EEPROM).
[0]
*
Off
[1]
On
EN-30 Warning parameter
Range:
Function:
[0000–
FFFF hex]
Read-only. Displays the Ethernet/IP specific 16-bit
status-word.
Bit
Description
0
Owned
1
Not used
2
Configured
3
Not used
4
Not used
5
Not used
6
Not used
7
Not used
8
Minor recoverable fault
9
Minor unrecoverable fault
10
Major recoverable fault
11
Major unrecoverable fault
12
Not used
13
Not used
14
Not used
15
Not used
Table 3.15 Bit Description
EN-31 Net Reference
Option:
Function:
Read-only. Displays the reference source in Instance
21/71.
[0]
*
Off
Reference from the network is not active.
[1]
On
Reference from the network is active.
EN-32 Net Control
Option:
Function:
Read-only. Displays the control source in Instance
21/71.
[0]
*
Off
Control via the network is not active.
[1]
On
Control via the network is active
EN-33 CIP Revision
Option:
Function:
Read-only. Displays the CIP-version of
the option software.
[0] Major version (00 - 99)
[1] Minor version (00-99)
EN-34 CIP Product Code
Range:
Function:
201
*
[0 - 65535]
Read-only. Shows the CIP product code.
EN-35 EDS Parameter
Range:
Function:
0
*
[0 - 0]
Parameter Description