[2316] Maintenance
Text
[2580] Pump Status
[2581] Pump Status
Status for the operation of each
individual pump controlled by the Pump
Controller.
K-20 Display Line 1.1 Small
Option: Function:
Select a variable for display in line 1, left position.
The options are the same as those listed under K-2#.
K-21 Display Line 1.2 Small
Option: Function:
Select a variable for display in line 1, middle position.
The options are the same as those listed under K-2#.
K-22 Display Line 1.3 Small
Option: Function:
Select a variable for display in line 1, right position.
The options are the same as those listed under K-2#.
K-23 Display Line 2 Large
Option: Function:
Select a variable for display in line 2.
The options are the same as those listed under K-2#.
K-24 Display Line 3 Large
Option: Function:
Select a variable for display in line 3.
The options are the same as those listed under K-2#.
K-25 Quick Start
Array [20]
Range:
Function:
0
*
[0 -
9999]
Define up to 50 parameters to appear in the Q1
Quick Start, accessible via the [Quick Menu] key on
the keypad. The parameters are displayed in the Q1
Quick Start in the order they are programmed into
this array parameter. Delete parameters by setting
the value to 0000.
For example, this can be used to provide quick,
simple access to just 1 or up to 50 parameters
which require changing on a regular basis (for
example, for plant maintenance reasons) or by an
OEM to enable simple commissioning of their
equipment.
3.1.4 K-3# Keypad Custom Readout
It is possible to customize the display elements for various
purposes:
•
Custom readout. Value proportional to speed
(linear, squared, or cubed depending on unit
selected in
parameter K-30 Unit for Custom
).
•
Display text. Text string stored in a parameter.
Custom readout
The calculated value to be shown is based on the settings
in:
•
Parameter K-30 Unit for Custom Readout
•
Parameter K-31 Min Value of Custom Readout
(linear only).
•
Parameter K-32 Max Value of Custom Readout
•
Parameter F-17 Motor Speed High Limit [RPM]
•
Parameter F-15 Motor Speed High Limit [Hz]
•
Actual speed.
Illustration 3.3 Custom Readout
The relation depends on the type of unit selected in
parameter K-30 Unit for Custom Readout
Unit type
Speed relation
Dimensionless
Linear
Speed
Flow, volume
Flow, mass
Velocity
Length
Temperature
Pressure
Quadratic
Power
Cubic
Table 3.2 Speed Relations for Different Unit Types
K-30 Unit for Custom Readout
Option:
Function:
Program a value to be shown in the LCP display-
keypad. The value has a linear, squared, or cubed
relation to speed. This relation depends on the
unit selected (see
). The actual calculated
value can be read in
, and/or shown in the display by selecting
Parameter Description
AF-600 FP
™
Programming Guide
DET-620D
03/2016 All rights reserved.
29
3
3