1. SAFETY INSTRUCTIONS
• The unit should only be used by a qualifi ed dental
professional.
• Be sure to follow the instructions in order to use the unit
correctly and to safeguard the patient and user.
• Patients as well as dental professionals should always use
appropriate safety precautions. Use the D-Light Pro curing
light with great care and carefully comply with all safety
precautions, including wearing suitable light fi ltering
safety glasses or goggles for the operator, assistant and
patient.
• For working with the unit, the owner must provide the
person(s) with the written operating instructions in an
understandable format as well as in the relevant
language(s). The owner is fully responsible to assure that
the D-Light Pro unit is in a safe working condition at all
times. If in doubt, do not use the unit and contact the
supplier.
• Prior to use, make sure that the unit is working normally
and safely. It should also be checked on a regular basis.
• Keep the unit out of the reach of infants or children.
• Do not use the unit on patients with a history of eye
disease such as cataract or retinal problems. This may
cause eye damage.
• The unit must not be disassembled or remodeled. This
may cause the unit to leak, generate heat, ignite or
explode.
• Only authorized technicians can repair the D-Light Pro
curing light, battery packs and charging station.
• Use of accessories not mentioned in this manual may
result in unsafe conditions and/or reduced product
performance. For this reason, use only factory authorized
accessories.
• The unit should not be handled with wet (gloved) hands.
This may cause a breakdown.
• The unit should not be exposed to direct sunlight, dust, a
wet environment or placed near a heater.
CONTENTS
1. Safety instructions
2. Features
3. Indications
4. Identifi cation of parts
5. Setup
6. Operation
7. Autoclaving and care of the unit
8. Troubleshooting
9. Disposal
10. Warranty & Repair
11. Packaging
12. Equipment class
13. Specifi cations
14. Explanation of Symbols and Storage
15. Contact Information
16. EMC Tables
• Make certain there is a match between incoming power
supply and the product electrical requirement. Do not use
the recharger with voltages diff erent than stated in this
manual or labeled on the equipment.
• Do not touch the inside of the battery compartment or
the contact points of the battery charger directly with the
hands or any metal objects. This may cause a breakdown.
• The battery should not be thrown into a fi re or heated. It
should not be struck with a sharp object or with force,
disassembled or remodeled. This may cause the battery to
leak, generate heat, ignite or explode.
• Do not allow the battery contact points to touch other
metal objects. Do not carry or store the battery next to
metal objects in order to avoid accidental contact with the
battery contact points.
• Do not charge, use or leave the battery in high
temperatures, near fi re or in direct sunlight, etc.
• Store the unit away from fl ammable materials.
• If the lithium-polymer battery should leak, do not touch
the liquid. In case of skin contact, fl ush immediately with
tap water because the liquid may be corrosive and cause
skin irritation or damage.
• If any liquid leaks from the battery and comes into contact
with the eyes, do not rub. Flush immediately with tap
water and seek medical attention. The liquid may cause
eye irritation or damage.
• Voltage is present in the charging station and battery
packs: do not open! Operate only in dry conditions. Never
manipulate with wet hands as this may cause an electrical
shock.
• If the battery or unit should begin to smoke, emit a bad
odour, deform or discolor during irradiation, charging or
storage, then discontinue usage immediately. Continued
usage may cause the battery to leak, and/or the unit to
generate heat, ignite or explode.
• Avoid sudden or strong impacts to the handpiece. This
may cause a breakdown or a reduction in the amount of
light emitted.
• Do not use mobile phones or other hand-held electronic
devices at the same time as the D-Light Pro.
• The light guide and eye-protection shield (either hard or
soft version) should be attached correctly in order to
ensure that they do not become detached during use.
Check routinely. Should they become loose or cracked,
then discontinue their use to avoid hazards such as
swallowing or inhalation. Make sure to fi x the eye-
protection shield correctly.
• If the light guide should crack or break, immediately
discontinue use. The light guide is made of glass and there
is a possibility of fragments accidentally being displaced
into the mouth.
• Do not look directly into the light emitted through the
light guide. This may cause eye damage. Prior to use, be
sure to fi x the eye-protection shield (either hard or soft
version).
• Prolonged usage of any curing light can increase
temperature. Extended usage near pulp and soft tissues
should be avoided to prevent injury. Curing near or around
sensitive tissues should be performed in short time
DLIGHT® PRO
DUAL WAVELENGTH LED CURING LIGHT
intervals. The Low Power mode (LP) can also be used to
limit heat generation when close to the pulp.
• If the handpiece is not used for an extended period of
time, or the unit is being transported, then the battery
should be removed from the handpiece or charging
station.
• Maintain adequate infection control measures when using
the D-Light Pro in the oral cavity, and execute the
appropriate hygiene plan after usage with patients.
• Protect the D-Light Pro from contamination by using
protective plastic barrier-sleeves. These sleeves are
intended for single-use; discard after each patient to
prevent possible cross-contamination. Protective plastic
barrier-sleeves are not needed when the light-guide and
handpiece sleeve are autoclaved between each patient.
• When using protective plastic barriers (bags, shields, etc.)
with the D-Light Pro, be certain that these are securely
affi x to avoid patient aspiration and treatment
complications.
• Do not use the Detection mode (DT) in conjunction with
caries detection dyes.
• Do not use if you have red-green color blindness or visual
impairment.
2. FEATURES
• LED powered visible light curing and visualisation unit
with high power output
• The D-Light Pro can polymerize light cured dental
materials, quickly and effi ciently.
• The D-Light Pro contains two diff erent types of LEDs
with diff erent wavelength peaks. This enables the
D-Light Pro to activate commonly used photo initiators
used in dentistry, like Camphorquinone (wavelength
peak of 468 nm) used in most light-cured materials, and
other initiators (wavelength peak of 400 +1-20 nm)
used in some light-cured dental materials.
• The D-Light Pro Detection mode (DT) assists the
visualisation of bacteria in plaque and carious lesions
and the identifi cation of fl uorescent materials.
• The D-Light Pro off ers an easy-to-use and elegant
stainless steel design. The design ensures a
user-friendly operation of the unit.
• Lithium polymer batteries, when fully charged, allow
for more than 45 individual irradiations of 20 seconds
duration each. The lithium polymer battery has no
memory eff ect, and a fast recharging speed of 75
minutes.
• The D-Light Pro is designed to off er a stable and
continuous high light output over several years.
• Built-in radiometer
• In addition to the light guide, the handpiece is
autoclavable once the internal electronic module and
battery pack have been removed.
• The D-Light Pro is under warranty for a period of 3
years, except the battery (1 year warranty) and
consumables (no warranty).
3. INDICATIONS
• Polymerisation of visible light curing materials curing
with a wavelength range of 400 to 480nm. In case of
questions about the wavelength ranges for certain
materials, please contact their respective
manufacturers.
• The Detection mode (DT) assists the visualization of
bacteria in plaque, fi ssures, infected dentin and the
presence of micro-leakage. It also helps to identify
fl uorescent restorative materials, and to evaluate the
depth of cracks in the tooth structure.
4. IDENTIFICATION OF PARTS
• Handpiece
Figure 1
• Electronic module
Figure 2
• Battery packs (x2)
Figure 3
• Light-guide
Figure 4
• Soft eye-protector shields (x3)
Figure 5
• Hard, oval eye-protection shield
Figure 5
• Charging station
Figure 6
• Power supply and cable
Figure 6
• EU/UK plug adapters
Figure 7
5. SETUP
• Carefully unpack all D-Light Pro components and
familiarize yourself with the individual items. Check for
completeness.
• First, check that the voltage indicated on the D-Light Pro
charging station name plate complies with the local
power supply.
Battery
• Prior to initial use or use after a long interval of non-use,
be sure to charge or recharge the batteries completely.
Use the original charging station and lithium polymer
battery only. Do not use any other battery chargers or
batteries.
• Connect the power cord to the charging station, and the
plug of the power cord to the mains power outlet
(110-240V AC) (Figure 8)
• Insert the batteries fully onto the docking ports of the
charging station until you hear/feel a ‘click’ (Figure 9)
• There is a LED corresponding to each docking port.
When the LED is illuminated, the battery is in the process
of being charged. When the LED turns off , then charging
is completed. Two batteries can be simultaneously
charged.
• Do not connect the depleted battery pack to the
charging station until it is properly cleaned and
disinfected.
• The time to fully charge an empty battery is
approximately 75 minutes.
• When the D-Light Pro is not in use for a prolonged
period of time, the battery pack should be disconnected
from the handpiece; or the handpiece/battery should be
in the “off ” position.
• Batteries may be stored on the docking ports of the
charging station as long as there is power to the
charging station.
EN
DE
FR
IT
ES
NL
DA
SV
NO
PT
FI
EL
406950-GC-D-LIGHT DUO-IFU-OOST ok.indd 2
13/10/16 15:57
Summary of Contents for D-Light Pro
Page 16: ...16 8 3 3 9 10 3 12 GC Europe 406950 GC D LIGHT DUO IFU OOST ok indd 16 13 10 16 15 57...
Page 82: ...82 EN 13060 2004 A2 2010 S 8 3 LED 406950 GC D LIGHT DUO IFU OOST ok indd 82 13 10 16 15 57...
Page 124: ...124 8 3 9 10 3 12 GC Europe 406950 GC D LIGHT DUO IFU OOST ok indd 124 13 10 16 15 57...