1. INSTALLATION & WIRING
1-5
Ground
Grounding guidelines
:
• The ground wire (local supply) should be 2sq or higher.
• The length of the ground wire should be as short as possible.
• For an FRP vessel, fasten a 20 cm
×
30 cm earthing plate to the outside of the boat’s
hull and attach the ground wire to a bolt on the plate.
• Attach a closed-end lug (
) to the ground wire. Do not use an open-end lug
(
).
• External equipment whose signal line is connected to ground cannot be directly
connected to this equipment if the positive polarity of the vessel’s DC power is con-
nected to ground.
MJ-A6SPF pin assignments (NMEA0183-1/2)
MJ-A7SPF pin assignments (NMEA0183-3)
Connector
Color
Remarks
1
TD1/2-A
White
NMEA0183
2
TD1/2-B
Black
3
RD1/2-H
Yellow
4
RD1/2-C
Green
5
GND
6
GND
Drain Wire
Connector
Color
Remarks
1
TD3-A
White
NMEA0183
2
TD3-B
Black
3
RD3-H
Yellow
4
RD3-C
Green
5
EXT-BUZZER 12V
Red
6
EXT-BUZZER Blue
7
GND
Drain Wire
CAUTION
Do not fail to ground the display unit.
If the ground is poor or there is no
ground, the radar and other equipment
may pick up interference.
Summary of Contents for FR-10
Page 1: ...OPERATOR S MANUAL www furuno com MARINE RADAR Model FR 10 FR 12 ...
Page 16: ...EQUIPMENT LIST xiv This page is intentionally left blank ...
Page 36: ...1 INSTALLATION WIRING 1 20 This page is intentionally left blank ...
Page 122: ...6 RADIO OPERATION 6 4 This page is intentionally left blank ...
Page 136: ...8 MAINTENANCE TROUBLESHOOTING 8 8 This page is intentionally left blank ...
Page 163: ...D 1 1 F eb 2 022 H M AKI ...
Page 164: ...D 2 1 Feb 2022 H MAKI ...
Page 165: ...D 3 1 Feb 2022 H MAKI ...
Page 166: ...D 4 1 Feb 2022 H MAKI ...