2. OPERATION
2-23
1. Press the
EBL
key to select [EBL 1].
2. Use the cursorpad to put the cursor on the center of the target A, then press the
ENTER
key.
3. Press the
EBL
key again. The origin of the EBL moves to the cursor position.
4. Use the cursorpad to put the cursor on the center of the target B, then press the
ENTER
key.
5. Press the
VRM
key to select [VRM 1].
6. Use the cursorpad to set the VRM on the inner edge of the target B.
7. Read the bearing and range indications at the bottom of the screen.
The range and bearing to another target (C and D in the figure above) can be mea-
sured using [EBL 2] and [VRM 2].
To cancel the this function, turn off the EBL and VRM.
EBL origin
+
+
Target B
Range/bearing between
targets A and B
Range/bearing between
targets C and D
EBL 2
VRM 2
EBL 1
VRM 1
EBL
4 5 . 0
R
3 2 7 . 0
R
VRM
0 . 5 5 0 NM
0 . 5 5 0 NM
Target A
Target D
Target C
2 5 5 . 5
R 1 . 0 9 4 NM
V E C T T R U E 0 5 : 0 0
+