2. OPERATION
2-52
[Plotter Brill]: Adjust the brilliance of plotter (Setting range: [1] to [4]).
[Depth Line Brill]: Adjust the brilliance of depth lines (Setting range: [1] to [4]).
[Viewing Position]: Adjust the viewing position between the installation position and
user (Setting range: [Left], [Left-Center], [Center], [Right-Center], [Right]).
[Display Color]: Adjust the display color (Setting range: [Day], [Night], [Twilight], [Cus-
tom]).
[Echo Color*]: Adjust the echo color (Setting range: [Yellow], [Green], [Orange],
[Multi]).
[Background Color*]: Adjust the background color (Setting range: [Black], [DK Blue],
[Blue], [White]).
[Character Color*]: Adjust the character color (Setting range: [Green], [Red], [White]).
*: Available only when the [Display Color] sets to [Custom].
[Menu Transparency]: You can select the degree of transparency of the menu window
so the menu window does not hide the echo display. [4] is the greatest degree of trans-
parency. [Off] functions to hide the echo display behind the menu window completely.
[Echo Color Mode]: You can select the color palette from [System] or [Custom]. [Sys-
tem] is the preset color palette and [Custom] is the color palette you can set yourself.
This function is not available in the [IEC] or [Russian-River] mode.
[Custom Echo Color]: You can customize the echo color with the following two meth-
ods.
• Method 1:
1) Select the echo rank to change
on the [Rank] (setting range: 1 - 31).
2) Set the RGB values for selected
echo rank on the [Red], [Green] and
[Blue] (setting range: 0 - 255).
• Method 2:
1) Select [31] on the [Rank].
2) Set the RGB values for 31 echo
rank on the [Red], [Green] and
[Blue] (setting range: 0 - 255).
3) Interpolate the RGB values be-
tween the maximum rank and minimum rank on the [Fitting To Curve] with the fol-
lowing curves (setting range: -20 to 20).
Setting range > 0: Logarithmic curve, useful to emphasize the weak echoes.
Setting range = 0: Straight line
Setting range < 0: Exponential curve, useful to emphasize the strong echoes.
Summary of Contents for FR-10
Page 1: ...OPERATOR S MANUAL www furuno com MARINE RADAR Model FR 10 FR 12 ...
Page 16: ...EQUIPMENT LIST xiv This page is intentionally left blank ...
Page 36: ...1 INSTALLATION WIRING 1 20 This page is intentionally left blank ...
Page 122: ...6 RADIO OPERATION 6 4 This page is intentionally left blank ...
Page 136: ...8 MAINTENANCE TROUBLESHOOTING 8 8 This page is intentionally left blank ...
Page 163: ...D 1 1 F eb 2 022 H M AKI ...
Page 164: ...D 2 1 Feb 2022 H MAKI ...
Page 165: ...D 3 1 Feb 2022 H MAKI ...
Page 166: ...D 4 1 Feb 2022 H MAKI ...