2. OPERATION
2-22
2. Use the cursorpad to place the EBL through the center of the target. Read the dis-
tance at the bottom left corner of the screen. The cursor on the EBL provides an
estimate of the range to a target.
3. To anchor the EBL, press the
ENTER
key. To reactivate the EBL, press the
EBL
key again.
Note:
To cancel the EBL, press the
CANCEL/HL OFF
key.
4. To erase a EBL, press the
EBL
key to select the EBL to erase. Press the
CAN-
CEL/HL OFF
key to erase the EBL and its indication.
2.19.2
EBL reference
"R" (relative) follows the EBL indication if the bearing is relative to the heading of your
ship. "T" (true) follows the EBL indication if the bearing is in reference to the north. You
can select relative or true in the head up mode. The bearing indication is true in all oth-
er modes. True bearing requires a heading sensor.
1. Press the
MENU
key to open the menu.
2. Press
or
to select [Others], then press the
ENTER
key.
3. Press
or
to select [EBL Reference], then press the
ENTER
key.
4. Press
or
to select [Relative] or [True] then press the
ENTER
key.
5. Press the
MENU
key to close the menu.
2.20
How to Measure the Range and Bearing Between
Two Targets
You can move the origin of the EBL to measure the range and bearing between two
targets.
+
EBL
2 7 0 . 0
R
4 5 . 0
R
EBL 1
EBL 2
Target
Cursor (+)
The currently active EBL
is in a rectangle.
EBL 1 bearing
EBL 2 bearing
Cursor range and bearing
VECTOR:TRU 06:00
+ 0.0°R 0.000NM
Summary of Contents for FR-10
Page 1: ...OPERATOR S MANUAL www furuno com MARINE RADAR Model FR 10 FR 12 ...
Page 16: ...EQUIPMENT LIST xiv This page is intentionally left blank ...
Page 36: ...1 INSTALLATION WIRING 1 20 This page is intentionally left blank ...
Page 122: ...6 RADIO OPERATION 6 4 This page is intentionally left blank ...
Page 136: ...8 MAINTENANCE TROUBLESHOOTING 8 8 This page is intentionally left blank ...
Page 163: ...D 1 1 F eb 2 022 H M AKI ...
Page 164: ...D 2 1 Feb 2022 H MAKI ...
Page 165: ...D 3 1 Feb 2022 H MAKI ...
Page 166: ...D 4 1 Feb 2022 H MAKI ...