2. OPERATION
2-24
2.21
How to Select a Pulselength
The pulselength in use appears at the upper-left position on the screen. The
pulselengths are set to each range scale and custom setup. You can change the
pulselength on the 1.5 nm or 3 nm range with the following procedure. Pulselength
cannot be changed on other ranges. (You can change the pulselength on the 2 nm or
4 nm range in the [Russian-River] mode.) Use a longer pulse when your purpose is
long range detection. Use a shorter pulse when the resolution is important.
Note 1:
When the DRS4DL; is connected, this menu is not available.
Note 2:
Press the
CUSTOM
key several times to activate the [Echo] menu until the
[CS 1] (2, 3) indication (custom setting) disappears from the screen.
1. Press the
MENU
key to open the menu.
2. Use
or
to select [Echo] and press
ENTER
.
3. Use
or
to select [Pulse Length] and press
ENTER
.
4. Use
or
to select [Short] or [Long] then press
ENTER
. The pulselength indi-
cation at the upper-left corner changes according to your selection as shown be-
low.
• 1.5 nm (or 2 nm in the [Russian-River] mode): "S2" for [Short] pulse, "M1" for
[Long] pulse.
• 3 nm (or 4 nm in the [Russian-River] mode): "M1" for [Short] pulse, "M3" for
[Long] pulse.
5. Press the
MENU
key to close the menu.
Summary of Contents for FR-10
Page 1: ...OPERATOR S MANUAL www furuno com MARINE RADAR Model FR 10 FR 12 ...
Page 16: ...EQUIPMENT LIST xiv This page is intentionally left blank ...
Page 36: ...1 INSTALLATION WIRING 1 20 This page is intentionally left blank ...
Page 122: ...6 RADIO OPERATION 6 4 This page is intentionally left blank ...
Page 136: ...8 MAINTENANCE TROUBLESHOOTING 8 8 This page is intentionally left blank ...
Page 163: ...D 1 1 F eb 2 022 H M AKI ...
Page 164: ...D 2 1 Feb 2022 H MAKI ...
Page 165: ...D 3 1 Feb 2022 H MAKI ...
Page 166: ...D 4 1 Feb 2022 H MAKI ...