Fig. 28: SHDSL interface (RJ45 connector)
bintec R3400
In 2 wire mode, the wire pairs a1 and b1 are used. In 4 wire mode, the additional wire pairs
a2 and b2 are used.
The pin assignment for the SHDSL interface (RJ45 connector) is as follows:
RJ45 socket for SHDSL connection bintec R3400
Pin
Function
1
Not used
2
Not used
3
Not used
4
Line a1
5
Line b1
6
Not used
7
Line a2
8
Line b2
The SHDSL interface on
bintec R3800
is connected via an RJ45 connector. The cable
supplied connects the RJ45 connector needed for the device to an RJ45 connector needed
for the SHDSL connection.
The following pins are used for the SHDSL connection:
Fig. 29: SHDSL interface (RJ45 connector)
bintec R3800
The use of wire pairs can be configured in the
Funkwerk Configuration Interface
.
The pin assignment for the SHDSL interface (RJ45 connector) is as follows:
RJ45 socket for SHDSL connection bintec R3800
6 Technical data
Funkwerk Enterprise Communications GmbH
62
R1xxx/R3xxx/R4xxx