![Funkwerk Bintec R1200wu Reference Download Page 163](http://html1.mh-extra.com/html/funkwerk/bintec-r1200wu/bintec-r1200wu_reference_2346489163.webp)
Field
Description
•
@ "
: Other services can be selected:
(Allows 64 kpbs PPP data connections),
(Allows 56
kpbs PPP data connections),
; "
; "
,
; "
,
; '"
(Allows PPP connections with V.110 and bitrates of 9,600
bps, 14,400 bps, 19,200 bps, 38,400 bps),
;
(Allows PPP connections with V.120).
MSN
Enter the number used to check the called party number. For
the call to be accepted, it is sufficient for the individual numbers
in the entry to agree, taking account of
MSN Recognition
.
MSN Recognition
Select the mode your device is to use for the number comparis-
on for
MSN
with the called party number of the incoming call.
Possible values:
•
=$ 4
(default value)
•
4 =$ 33"
: Always select if your device is con-
nected to a point-to-point connection.
Bearer Service
Select the type of incoming call (service detection).
Possible values:
•
3 > ;%
(default value): Both data and voice calls.
•
3
: data call
•
;%
: Voice call (modem, voice, analog fax)
11.4 ADSL Modem
11.4.1 ADSL Configuration
In this menu, you make the basic settings for your ADSL connection.
R3000
and
R3000w
are ADSL multiprotocol routers with integrated ADSL(2+) modem and
automatic ISDN backup. The ADSL modem on the
R3000
/
R3000w
is compatible with AN-
NEX A and ANNEX B standards and so can be used universally in several countries. It is
particularly suitable for high-speed Internet access and remote access use in SMEs or re-
mote offices. The device is supplied ex works with 10 IPSec tunnels including hardware ac-
Funkwerk Enterprise Communications GmbH
11 Physical Interfaces
R1xxx/R3xxx/R4xxx
137