![Funkwerk Bintec R1200wu Reference Download Page 151](http://html1.mh-extra.com/html/funkwerk/bintec-r1200wu/bintec-r1200wu_reference_2346489151.webp)
Field
Description
command ATX3&K3\V1 is the default setting (the modem does
not wait for a free signal before dialling).
You can add other AT commands by separating them with
semicolons. The entry is limited to 50 characters. Make sure
you enter the command for activating the XON/XOFF software
flow control. This is proprietary and cannot be set automatically.
The command sequence can be obtained from your modem
manual or the manufacturer.
APN (Access Point
Name)
Only for
AUX Port Status
enabled
If GPRS is used, the so-called Access Point Name of the pro-
vider must be entered, e.g. internet.eplus.de for eplus and so
on.
A maximum of 40 characters can be entered. If no APN or an
incorrect APN is entered, a configured GPRS connection will
not function.
11.2 Ethernet Ports
An Ethernet interface is a physical interface for connection to the local network or external
networks.
The Ethernet ports
ETH1
to
ETH4
are assigned to a single logical Ethernet interface in ex
works state. The logical Ethernet interface
!
is assigned, and preconfigured with
IP
Address
and
Netmask
.
The logical Ethernet interface
!
is assigned to the
ETH5
port and is not precon-
figured.
Note
To ensure your device can be reached, when splitting ports make sure that Ethernet
interface
!
is assigned - with the preconfigured IP address and netmask - to a
port that can be reached via Ethernet. If in doubt, carry out the configuration using a
serial connection via the
Console
interface.
ETH1 - ETH4
Funkwerk Enterprise Communications GmbH
11 Physical Interfaces
R1xxx/R3xxx/R4xxx
125