Field
Description
•
4& 4
: You can select a leased line.
•
D!- -( +"
: EQ-SIG S2M User Profile
•
D!- -( *+"
: Q-SIG S2M Network Profile
ISDN Line Framing
Only if
Port Usage
is selected.
Select the framing type for layer 1.
Possible values:
•
6=6 -"
(default value)
•
* 6=6
The default value can be left in the majority of scenarios. You
can use the
* 6=6
option if required (e.g. in Sweden and
France), if the device is to be connected to a PABX.
P-P Base Number
Only if
Port Usage
is not
*
,
<% <% /,"
or
4& 4
.
.
Enter the basic number of the connection.
With incoming calls, this basic number is removed from the
called number (Called Party Number).
With outgoing calls, this basic number is attached to the call
number to be called (Calling Party Number).
Channel Selection
Only if
Port Usage
=
5=@ -3* -( +"
,
5=@ -3*
-( *+"
,
D!- -( +"
or
D!- -( *+"
.
An additional option is provided in order to guarantee the com-
patibility with special providers: If you set the switch type appro-
priately, you can select a value for the variable
Channel Selec-
tion
. This defines how the B channel is selected for an outgoing
call.
Possible values:
•
1) 6/
(default value): The device tells the PABX that
all channels are available. The exchange of the PABX selects
the channel to be used.
11 Physical Interfaces
Funkwerk Enterprise Communications GmbH
132
R1xxx/R3xxx/R4xxx