5.2 Installing the components in the rack
Mounting the rail systems
Figure 53: Fit the Left Support System in the PRIMECENTER Rack
CAUTION!
When using telescopic rails, the rack must be protected against tilting.
1. Identify the right and the left rail (see label or imprint on the rail).
2. Position the rail on the rear left support bracket by inserting the retaining bolts (1).
3. Press the rail together (2).
4. Move the rail outwards until the designated position (grid of support upright) is
reached (3).
The black bolts must lock in the corresponding holes.
5. Press the bracket backwards until the rail engages (4).
CAUTION!
l
The toothed levers must be closed.
l
The two black bolts must be flush with the bracket.
ETERNUS CS800
82