3.1 Server
CAUTION!
The server is automatically set to a mains voltage in the range 100 V - 240 V.
You may only operate the server if its rated voltage range corresponds to the
local mains voltage.
Connect the power cord with the insulated connector to the power supply unit of the
server, and plug the power plug into a grounded outlet on the mains socket strip on
the rack (see Technical Manual of the rack).
A phase redundancy in the power supply of the server can be set up if each of
the power supply units is either connected to two different phases or to two
separate circuits of the internal power supply network.
Using the cable clamp
You can secure the power cords in a cable clamp to ensure that the insulated connectors
cannot be disconnected from the server accidentally.
Figure 12: Cable clamp
1. Pull the cable clamp up (2).
2. Thread the power cord through the cable clamp (1).
3. Press the cable clamp down until it engages to secure the cable (3).
ETERNUS CS800
48
Summary of Contents for ETERNUS CS800 S6
Page 1: ...English ETERNUS CS800 S6 User Guide V3 2 7 Edition April 2017 ...
Page 131: ...7 3 The Remote Management Console Figure 98 Remote Management Pages Map ETERNUS CS800 131 ...
Page 173: ...8 8 AIS Connect Figure 132 AISConnect Wizard Confirm ETERNUS CS800 173 ...
Page 449: ...16 2 Storage Subsystem Figure 313 Inserting the 3 5 inch HDD module ETERNUS CS800 449 ...