10.4 OST Configuration
2. Enter information about the LSU.
Storage Server
Select the storage server that will contain the new
LSU.
Available Capacity
(Recommended for best performance) Select this
option to add an LSU that uses the available capacity
on the system.
You cannot add an available capacity LSU to a
storage server that already contains an LSU. Also, if
you add an available capacity LSU to a storage
server, you cannot add additional LSUs to that same
storage server.
After you add an LSU that uses the
Available
Capacity
option, you cannot change the LSU to
use the
Specific Capacity
option. Instead, you
must delete the LSU, then add a new LSU and
choose the
Specific Capacity
option (see
).
Specific Capacity
Select this option to specify the physical capacity of
the LSU, and then enter the following information.
l
LSU Name
- Enter the name of the LSU.
l
Physical Capacity
- Enter the physical capacity of
the LSU (1 to 1048576 GB).
Fujitsu Technology Solutions recommends
setting LSUs to maximum size (1048576 GB)
because spanning them on a backup is not
possible.
3. (Optional) In the
Description
box, enter a brief description of the LSU.
4. (Optional) Select the
Enable Automatic Image Replication
check box to automatically
replicate (duplicate) data on the LSU to a remote LSU on another ETERNUS CS800.
Automatic Image Replication (AIR) is disabled by default. If enabled, data on an LSU
is automatically replicated to a remote LSU that resides on a ETERNUS CS800 in a
different NetBackup domain. The timing of the duplication, as well as the backup
images that are duplicated, are determined by the storage lifecycle policies (SLPs)
configured in NetBackup.
OST AIR requires NetBackup 7.1 or higher. For information about configuring
NetBackup for Automatic Image Replication, see the
ETERNUS CS800 NetBackup and
Backup Exec OST Configuration Guide
(6-67079).
ETERNUS CS800
241
Summary of Contents for ETERNUS CS800 S6
Page 1: ...English ETERNUS CS800 S6 User Guide V3 2 7 Edition April 2017 ...
Page 131: ...7 3 The Remote Management Console Figure 98 Remote Management Pages Map ETERNUS CS800 131 ...
Page 173: ...8 8 AIS Connect Figure 132 AISConnect Wizard Confirm ETERNUS CS800 173 ...
Page 449: ...16 2 Storage Subsystem Figure 313 Inserting the 3 5 inch HDD module ETERNUS CS800 449 ...