SPECIFICATION SUMMARY
Type
Function
UTY-
ALGXZ1
UTY-
PLGXA2
Option
UTY-
PLGXR2
Option
UTY-
PLGXE2
Option
UTY-
PLGXP2
Option
UTY-
PLGXX2
Option
Remark
System specification
Max. System Controller Lite per VRF
Network
1
Max. VRF networks supported
1
Max. indoor units / remote controller groups
per VRF network
400
Max. indoor units / remote controller groups
per System Controller Lite
400
Site supervision
Multiple sites display
10
2D/3D graphical layout view
.
List display
z
Quick control from display available.
Tree display
z
Quick control from display available.
Operation
control
Individual
Start/Stop, Operation mode, Room
temperature
z
Fan speed, Airflow direction
z
Economy mode
z
Antifreeze
z
Remote control prohibition setting
z
Temperature upper and lower limit setting
z
Filter sign reset
z
Human sensing
z
Schedule
Annual schedule
z
Week of year, day of month, day of
week setting.
Holiday special day settings.
Low noise mode weekly schedule
z
Outdoor unit control only.
Group
management
Number of groups
400
Group in group
3 Levels
Lv.1 – 2 – 3.
Max. overlap definitions
400
1 unit may belong to up to 400
groups.
Auto generation
z
By site, building and floor.
Others
Memory operation
z
Operation pattern memorized and
reused.
Pattern operation
z
Reuse operation pattern once used.
Operation status
monitoring
Controlled status
z
See items controlled by operation.
Special operation
z
Defrost, Oil Recovery.
Room Temp.
Room temperature
z
*
1
Error management
Error notification
z
Audible alarm
z
Error e-mail notification
z
History management
Error history
1 year
Operation control & status history
1 year
Energy saving
management
Indoor unit rotation
z
Outdoor unit capacity save
z
Peak cut control
1 month
Power consumption monitor
z
Electricity meters supported
200
Outdoor unit required per
connection
Power consumption information
3 years
Electricity charge
apportionment
Apportionment charge calculation
z
Apportionment charge bill creation
z
Tenant (block) setting
1600
Common facilities apportionment setting
z
Rated power consumption allotment setting
z
Electricity meters supported
200
Same meters used for energy
saving.
Electricity charge apportionment period
2 years
Prepaid air conditioning
z
Cooling and Heating information
z
Remote control
Internet, telephone line support
z
Max. client connection per server
5
Max. host connection from client
10
Data encryption
z
SSL used.
- (05 - 27) -
C
O
N
TRO
L
SY
ST
EM
C
O
N
TRO
L
SY
ST
EM
Summary of Contents for Airstage AGUA12TLAV1
Page 1: ...Small VRF system for light commercial and home use DESIGN TECHNICAL MANUAL ...
Page 22: ...1 GENERAL INFORMATION DTV_J2U045E_06 CHAPTER01 2018 03 16 ...
Page 38: ...2 MODEL SELECTION DTV_J2U045E_05 CHAPTER02 2018 03 16 ...
Page 113: ...3 OUTDOOR UNITS DTV_J2U045E_02 CHAPTER03 2016 04 13 ...
Page 122: ...5 WIRING DIAGRAM MODELS AOU36RLAVM AOU48RLAVM 03 08 OUTDOOR UNITS OUTDOOR UNITS ...
Page 123: ... MODELS AOU60RLAVM 03 09 OUTDOOR UNITS OUTDOOR UNITS ...
Page 127: ... SOUND LEVEL CHECK POINT Microphone Airflow 39 3 8 in 1 m 03 13 OUTDOOR UNITS OUTDOOR UNITS ...
Page 130: ...4 INDOOR UNITS DTV_VR2U025E_10 CHAPTER04 2018 01 26 ...
Page 203: ...4 WIRING DIAGRAMS 4 1 COMPACT CASSETTE TYPE MODEL AUUA4TLAV1 04 70 INDOOR UNITS INDOOR UNITS ...
Page 207: ...4 4 MINI DUCT TYPE MODEL ARUL4TLAV1 04 74 INDOOR UNITS INDOOR UNITS ...
Page 211: ... MODELS ARUH72TLAV1 ARUH96TLAV 04 78 INDOOR UNITS INDOOR UNITS ...
Page 215: ...4 11 CEILING TYPE MODELS ABUA30TLAV ABUA36TLAV 04 82 INDOOR UNITS INDOOR UNITS ...
Page 217: ... MODELS ASUA12TLAV1 ASUA14TLAV1 04 84 INDOOR UNITS INDOOR UNITS ...
Page 218: ... MODELS ASUB18TLAV1 ASUB24TLAV1 04 85 INDOOR UNITS INDOOR UNITS ...
Page 219: ... MODELS ASUB30TLAV1 ASUB36TLAV1 04 86 INDOOR UNITS INDOOR UNITS ...
Page 220: ... MODELS ASUA7TLAV ASUA9TLAV ASUA12TLAV ASUA14TLAV 04 87 INDOOR UNITS INDOOR UNITS ...
Page 221: ... MODELS ASUB18TLAV ASUB24TLAV 04 88 INDOOR UNITS INDOOR UNITS ...
Page 361: ...5 CONTROL SYSTEM DTV_VR2U025E_14 CHAPTER05 2018 03 16 ...
Page 563: ...6 SYSTEM DESIGN DTV_J2U045E_05 CHAPTER06 2017 12 26 ...
Page 645: ...7 FUNCTION SETTING DTV_VR2U025E_12 CHAPTER07 2018 03 16 ...
Page 819: ...8 EXTERNAL INPUT OUTPUT DTV_VR2U025E_08 CHAPTER08 2017 12 26 ...
Page 878: ...9 NOTES DTV_VR2U025E_10 CHAPTER09 2017 12 26 ...
Page 894: ...10 OPTIONAL PARTS DTV_VR2U025E_12 CHAPTER10 2018 03 16 ...
Page 935: ...4 5 WIRING DIAGRAMS MODEL UTP RU01AH MODEL UTP RU01BH 10 40 OPTIONAL PARTS OPTIONAL PARTS ...
Page 936: ... MODEL UTP RU01CH 10 41 OPTIONAL PARTS OPTIONAL PARTS ...
Page 937: ... MODEL UTP RU04BH 10 42 OPTIONAL PARTS OPTIONAL PARTS ...