FUNCTIONS
z
MODEL: UTY-DTGYZ1
Item
Main unit
PC / Tablet
Description
Installation
Indoor unit registration
z
Indoor unit registration. Max. 400 units.
(Set data can be written to and read from USB flash drive)
Functions setting
z
Temperature set point limitation, external input, central
operation on/off setting.
Monitor
Display switching
z
z
Icon display, list display
Display units
z
z
ALL, group, individual (remote control group)
Monitor contents (icon
display)
z
z
Group name, operation, operation mode, set temperature,
time, errors, timer setting, filter sign, room temp., human
sensor, set temp. range
Monitor contents (list
display)
z
z
Group name, operation, operation mode, set temperature,
airflow, air direction, special operation, anti-freeze, time,
errors, timer setting, filter sign
Error list
z
z
Group name, remote control group name, address, error code
Special state
z
z
Display during special operation
Control
Control units
z
z
ALL, group, individual (remote control group)
Control contents
z
z
Operation, operation mode, set temperature, airflow,
RC Prohibition, filter sign reset
Detailed control contents
z
z
Air direction, energy saving, anti-freeze, test run
Individual setting reset of
airflow direction
z
Sets the position of indoor unit's airflow direction louver
individually.
Human sensor
z
Sets the human sensor on the indoor unit.
Setting temperature
limitation of room
z
z
Adjusts the upper and lower limits of temperature for the
indoor unit.
Setting
Language setting
z
z
Design considering multi-language correspondence. *
1
Date and time
z
z
Time display switching, year/month/day display switching,
system clock setting, summer time, internet time adjustment
setting
Time zone
z
z
Set the time zone of the area where this unit is used
Panel cleaning and
correction
z
Select display area for panel cleaning.
User can select black screen on display.
Group
z
z
Stages: Max. 3 stages Settable up to 400 groups.
(Set data can be written to and read from USB flash drive)
Background light and
beep sound
z
Backlighting off time and brightness setting, BEEP sound
operation setting
Password
z
Management level: 3 kinds
Schedule timer
z
z
Max. 30 items settable
Temperature range
z
Celsius/Fahrenheit switching, cooling, heating, and AUTO
each settable.
Network
z
z
function of Email notification for malfunction, or electricity
charge apportionment option is used via LAN
Low noise operation
z
z
"Low noise operation" is set to all the outdoor units registered
by this controller.
Electricity charge
apportionment
*
2
z
z
Start/stop of ECA, importing/exporting of ECA setting, and
exporting ECA data.
Remote language
additional registration
z
Additional language can be integrated on remote device by
creating language database.
Additional language is displayed on only the remote device
and touch panel controller cannot be added other language.
Auto OFF timer
z
Function to stop the operation automatically when a preset
time lapses after turning on the operation.
Set temperature auto
return
z
Function to restore the temperature to the original set
temperature when a preset time lapses after changing the set
temperature.
Display item setting
z
Sets the items to be displayed on the monitor.
Failure notification Email
z
Failure notification Email: Sends a notification Email to the
preset Email address in the event of failure.
Remote connection
setting
z
Create users: Max. 15 users, type, permissions, unit setting,
automatic logout time
Maintenance
Error history
z
z
Recording of Max. 10 errors each for touch panel controller
and each unit (indoor unit, outdoor unit)
Status history
z
z
Recording of Max. 100 operations each for each indoor unit.
Writable to USB flash drive.
Operation history
z
z
Recording of Max. 10000 operations. Writable to USB flash
drive.
Version display
z
z
Version display, TPC MAC address, software version, writing
the TPC information
- (05 - 35) -
C
O
N
TRO
L
SY
ST
EM
C
O
N
TRO
L
SY
ST
EM
Summary of Contents for Airstage AGUA12TLAV1
Page 1: ...Small VRF system for light commercial and home use DESIGN TECHNICAL MANUAL ...
Page 22: ...1 GENERAL INFORMATION DTV_J2U045E_06 CHAPTER01 2018 03 16 ...
Page 38: ...2 MODEL SELECTION DTV_J2U045E_05 CHAPTER02 2018 03 16 ...
Page 113: ...3 OUTDOOR UNITS DTV_J2U045E_02 CHAPTER03 2016 04 13 ...
Page 122: ...5 WIRING DIAGRAM MODELS AOU36RLAVM AOU48RLAVM 03 08 OUTDOOR UNITS OUTDOOR UNITS ...
Page 123: ... MODELS AOU60RLAVM 03 09 OUTDOOR UNITS OUTDOOR UNITS ...
Page 127: ... SOUND LEVEL CHECK POINT Microphone Airflow 39 3 8 in 1 m 03 13 OUTDOOR UNITS OUTDOOR UNITS ...
Page 130: ...4 INDOOR UNITS DTV_VR2U025E_10 CHAPTER04 2018 01 26 ...
Page 203: ...4 WIRING DIAGRAMS 4 1 COMPACT CASSETTE TYPE MODEL AUUA4TLAV1 04 70 INDOOR UNITS INDOOR UNITS ...
Page 207: ...4 4 MINI DUCT TYPE MODEL ARUL4TLAV1 04 74 INDOOR UNITS INDOOR UNITS ...
Page 211: ... MODELS ARUH72TLAV1 ARUH96TLAV 04 78 INDOOR UNITS INDOOR UNITS ...
Page 215: ...4 11 CEILING TYPE MODELS ABUA30TLAV ABUA36TLAV 04 82 INDOOR UNITS INDOOR UNITS ...
Page 217: ... MODELS ASUA12TLAV1 ASUA14TLAV1 04 84 INDOOR UNITS INDOOR UNITS ...
Page 218: ... MODELS ASUB18TLAV1 ASUB24TLAV1 04 85 INDOOR UNITS INDOOR UNITS ...
Page 219: ... MODELS ASUB30TLAV1 ASUB36TLAV1 04 86 INDOOR UNITS INDOOR UNITS ...
Page 220: ... MODELS ASUA7TLAV ASUA9TLAV ASUA12TLAV ASUA14TLAV 04 87 INDOOR UNITS INDOOR UNITS ...
Page 221: ... MODELS ASUB18TLAV ASUB24TLAV 04 88 INDOOR UNITS INDOOR UNITS ...
Page 361: ...5 CONTROL SYSTEM DTV_VR2U025E_14 CHAPTER05 2018 03 16 ...
Page 563: ...6 SYSTEM DESIGN DTV_J2U045E_05 CHAPTER06 2017 12 26 ...
Page 645: ...7 FUNCTION SETTING DTV_VR2U025E_12 CHAPTER07 2018 03 16 ...
Page 819: ...8 EXTERNAL INPUT OUTPUT DTV_VR2U025E_08 CHAPTER08 2017 12 26 ...
Page 878: ...9 NOTES DTV_VR2U025E_10 CHAPTER09 2017 12 26 ...
Page 894: ...10 OPTIONAL PARTS DTV_VR2U025E_12 CHAPTER10 2018 03 16 ...
Page 935: ...4 5 WIRING DIAGRAMS MODEL UTP RU01AH MODEL UTP RU01BH 10 40 OPTIONAL PARTS OPTIONAL PARTS ...
Page 936: ... MODEL UTP RU01CH 10 41 OPTIONAL PARTS OPTIONAL PARTS ...
Page 937: ... MODEL UTP RU04BH 10 42 OPTIONAL PARTS OPTIONAL PARTS ...