INDOOR UNIT
For the air conditioner to operate satisfactorily, install it as outlines in installation manual.
z
Indoor unit mounting position
●
Decide the mounting position with the customer
●
Install the unit level on a strong wall, floor, ceiling which is not subject to vibration.
●
The inlet and outlet ports should not be obstructed. The air should be able to blow all over the room.
●
Install the unit where the connection pipe can be easily installed.
●
Install the unit where the drain pipe can be easily installed.
●
Take servicing, etc. into consideration and leave the spaces. Also install the unit where the filter can be
removed.
●
Install the unit where satisfy the pipe length and hight.
z
Indoor unit mounting limitation
●
Install at a place that can withstand the weight of the indoor unit and install positively so that the unit will not
topple or fall.
●
Do not install the unit where there is the danger of combustible gas leakage.
●
Do not install the unit near heat sources and the location with high temperature.
●
Mount with the lowest moving parts at least 7ft. (2.4m) above floor or grade level.
●
Do not install the unit near a source of heat, steam, or flammable gas.
●
Do not use the unit for air conditioning or saving precision instrument, food, art, plants and animal as special
place.
●
If children may approach the unit, take preventive measures so that they cannot reach the unit.
●
Do not install where there is oily smoke, machine oil (i.e. factory), salty environment with direct sea breeze, and
too much of dust.
●
Install the unit where drainage does not cause any trouble.
●
Welding parts may be fretted if the unit is installed where corrosive gas such as sulphurous acid gas is
generated.
●
Control may not operate correctly if the unit is installed near machinery which emit electromagnetic wave.
●
Install the unit in a well-ventilated place avoiding rains and direct sunlight.
●
Install the unit where air from the outlet and noise do not disturb the neighbour.
●
Install the indoor and outdoor units, power wiring, signal wiring and remote control wiring 1 m away from
television and radio to avoid distorted images and noise. (However, distorted noise may not be avoidable even
if units and wiring mentioned above are installed 1m away from television and radio depending on conditions of
electromagnetic disturbance.)
●
When installing an indoor unit in a small room, a countermeasure must be taken to keep refrigerant concentration
limitations will never be exceeded even if there is a refrigerant leak.
●
A sound might be heard from the indoor unit such as a refrigerant flowing sound. For using in small and quiet
room such as bed room or hotel guest room, select the unit which has not exposed inside the room (Ex. Duct
type) .
- (06 - 11) -
SY
ST
EM
DE
SIGN
SY
ST
EM
DE
SIGN
Summary of Contents for Airstage AGUA12TLAV1
Page 1: ...Small VRF system for light commercial and home use DESIGN TECHNICAL MANUAL ...
Page 22: ...1 GENERAL INFORMATION DTV_J2U045E_06 CHAPTER01 2018 03 16 ...
Page 38: ...2 MODEL SELECTION DTV_J2U045E_05 CHAPTER02 2018 03 16 ...
Page 113: ...3 OUTDOOR UNITS DTV_J2U045E_02 CHAPTER03 2016 04 13 ...
Page 122: ...5 WIRING DIAGRAM MODELS AOU36RLAVM AOU48RLAVM 03 08 OUTDOOR UNITS OUTDOOR UNITS ...
Page 123: ... MODELS AOU60RLAVM 03 09 OUTDOOR UNITS OUTDOOR UNITS ...
Page 127: ... SOUND LEVEL CHECK POINT Microphone Airflow 39 3 8 in 1 m 03 13 OUTDOOR UNITS OUTDOOR UNITS ...
Page 130: ...4 INDOOR UNITS DTV_VR2U025E_10 CHAPTER04 2018 01 26 ...
Page 203: ...4 WIRING DIAGRAMS 4 1 COMPACT CASSETTE TYPE MODEL AUUA4TLAV1 04 70 INDOOR UNITS INDOOR UNITS ...
Page 207: ...4 4 MINI DUCT TYPE MODEL ARUL4TLAV1 04 74 INDOOR UNITS INDOOR UNITS ...
Page 211: ... MODELS ARUH72TLAV1 ARUH96TLAV 04 78 INDOOR UNITS INDOOR UNITS ...
Page 215: ...4 11 CEILING TYPE MODELS ABUA30TLAV ABUA36TLAV 04 82 INDOOR UNITS INDOOR UNITS ...
Page 217: ... MODELS ASUA12TLAV1 ASUA14TLAV1 04 84 INDOOR UNITS INDOOR UNITS ...
Page 218: ... MODELS ASUB18TLAV1 ASUB24TLAV1 04 85 INDOOR UNITS INDOOR UNITS ...
Page 219: ... MODELS ASUB30TLAV1 ASUB36TLAV1 04 86 INDOOR UNITS INDOOR UNITS ...
Page 220: ... MODELS ASUA7TLAV ASUA9TLAV ASUA12TLAV ASUA14TLAV 04 87 INDOOR UNITS INDOOR UNITS ...
Page 221: ... MODELS ASUB18TLAV ASUB24TLAV 04 88 INDOOR UNITS INDOOR UNITS ...
Page 361: ...5 CONTROL SYSTEM DTV_VR2U025E_14 CHAPTER05 2018 03 16 ...
Page 563: ...6 SYSTEM DESIGN DTV_J2U045E_05 CHAPTER06 2017 12 26 ...
Page 645: ...7 FUNCTION SETTING DTV_VR2U025E_12 CHAPTER07 2018 03 16 ...
Page 819: ...8 EXTERNAL INPUT OUTPUT DTV_VR2U025E_08 CHAPTER08 2017 12 26 ...
Page 878: ...9 NOTES DTV_VR2U025E_10 CHAPTER09 2017 12 26 ...
Page 894: ...10 OPTIONAL PARTS DTV_VR2U025E_12 CHAPTER10 2018 03 16 ...
Page 935: ...4 5 WIRING DIAGRAMS MODEL UTP RU01AH MODEL UTP RU01BH 10 40 OPTIONAL PARTS OPTIONAL PARTS ...
Page 936: ... MODEL UTP RU01CH 10 41 OPTIONAL PARTS OPTIONAL PARTS ...
Page 937: ... MODEL UTP RU04BH 10 42 OPTIONAL PARTS OPTIONAL PARTS ...